36
GA01423_002_A2 - 10/2008 - © Oerlikon Leybold Vacuum
Maintenance
5.1
Table - Maintenance
When the maintenance interval has been reached, contact Oerlikon Leybold
Vacuum to arrange the required maintenance. Never disassemble, reassem-
ble or alter the pump yourself. We are not responsible for any accidents cau-
sed by disassembly, assembly or alteration which was done by the user or
non-specialist.
Maintenance interval
Where to inspect
Yearly or every
Every two years or
After having
Remarks
8,000 hours
every 16,000 hours
pumped vapours
400x
Ball bearing
grease /
▲
❍
▲
Tip seal
✽
❍
▲
Seal
✽
❍
▲
O-ring
✽
❍
▲
Exhaust valve
✽
❍
▲
Purge
✽
❍
▲
Pin crank
▲
▲
▲
Stopper
▲
▲
▲
Vacuum pump itself
inside cleaning /
▲
inside cleaning /
▲
inside cleaning /
▲
✽
Small maintenance kit
❍
Large maintenance kit
▲
Replace in case of malfunction
Note 1: Exclusively use the specified DIS grease.
Note 2 : The maintenance interval is the time interval or running hours whichever is reached first.