Maintenance
63
GA03107_002_A4 - 09/2015 - © Oerlikon Leybold Vacuum
5.11 Maintenance Schedule
Process
Meas./test
quantity
Maintenance intervall
Remark
Check oil level
Min./max. oil level
in oil level glass
Before switching on and daily
Check oil level with the pump at stand-
still, see Section 3.1.1
Check the coupling for
running noises
Daily for ATEX operation
Check oil quality
Visual
Weekly
In the normal state LVO 100 is light
brown LVO 210 is yellow, clear and
transparent. In the case of black oil an oil
change is necessary, see Section 5.2.
Check oil quality
Neutralisation
value (DIN 51 558)
For normal operating conditions annu-
ally
When pumping corrosive vapours, in
the case of much dust and cyclic ope-
ration weekly to quarter yearly
If the neutralisation value of LVO 100 is
> 2, then an oil change will be required,
see Section 5.2.
Oil change
For normal operating conditions annu-
ally
When pumping corrosive vapours, in
the case of much dust and cyclic ope-
ration weekly to quarter yearly
See Section 5.2.
Clean motor fan and
cooling fins
The cleaning intervals will depend on
the ambient conditions.
See Section 5.4.
Check the oil level in
the shaft sealing ring
housing
The oil level in the oiler can be checked
during operation (see Section 4.2)
Exchange the oil for the
shaft sealing ring
housing.
after 3000 operating hours
See Section 5.3
Replace bearings and
coupling, completely
refurbish the pump
For ATEX applications every 15,000
operating hours or every three years
See Section 5.9
Summary of Contents for RUVAC WA
Page 67: ...Notes 67 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...
Page 68: ...68 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Declaration of Conformity ...
Page 69: ...69 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Incorporation Declaration ...
Page 71: ...Index 71 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...