Description
30
GA03107_002_A4 - 09/2015 - © Oerlikon Leybold Vacuum
1.3 Technical Data
For ATEX applications, only the values for 50 Hz apply.
RUVAC WA/WAU
251
501
1001
2001
Nominal pumping speed at 50 Hz
1)
m
3 .
h
-1
253
505
1000
2050
Max. pumping speed at 50 Hz
m
3 .
h
-1
210
410
800
1850
Nominal pumping speed at 60 Hz
1)
m
3 .
h
-1
304
606
1200
2460
Max. pumping speed at 60 Hz
m
3 .
h
-1
251
530
1000
2100
■
with backing pump TRIVAC
D 65 B
-
-
-
■
with backing pump SOGEVAC
SV 200
SV 300
SV 630 F
Ultimate partial pressure
2)
mbar
< 2
.
10
-5
< 8
.
10
-3
< 8
.
10
-3
< 8
.
10
-3
Ultimate total pressure
2)
mbar
< 8
.
10
-4
< 4
.
10
-2
< 4
.
10
-2
< 4
.
10
-2
Poss. cut-in pressure
2)
– RUVAC WA
mbar
90
100
60
30
Maximum allowable pressure differential
in continous operation
3)
mbar
80
80
80
50
Leak rate, integral
mbar · l · s
-1
≤ 5 · 10
-4
Permissible ambient temperatures
°C
12 - 40
Main supply IEC motor
8)
YY/Y V
220-240/
220-240/
220-240/
–
380-420
380-420
380-420
380-420
Temperature class
F
F
F
F
Motor power
kW
1.1
2.2
4.0
7.5
Nominal speed, 50/60 Hz
min
-1
3000 / 3600
Max. permissible speed
min
-1
3600
Motor protection category
IP
55
Oil filling for the bearing chamber
4)
1. Filling
5
/ 2. Filling 1. Filling
5
/ 2. Filling 1. Filling
5
/ 2. Filling 1. Filling
5
/ 2. Filling
vertical pumping action, approx.
l
0.5 / 0.4
0.9 / 0.8
2.0 / 1.8
4.2 / 3.6
horizontal pumping action, approx.
l
0.5 / 0.4
0.8 / 0.7
1.2 / 1.1
2.0 / 1.8
Oil filling of the shaft sealing ring housing
l
0.6
1.0
1.3
1.6
Connection flanges
DN
63 ISO - K
63 ISO - K
100 ISO - K
160 ISO - K
Weight WA / WAU
kg
85 / 89
128 /133
220 /225
400 / 406
Noise level
6)
dB (A)
< 64
< 67
< 75
< 80
1)
To DIN 28 400 and subsequent numbers
2)
With double-stage rotary vane vacuum pump TRIVAC, resp. single-stage rotary vane vacuum pump SOGEVAC
(Type of backing pump look at max. pumping speed). When using 2-stage backing pumps the ultimate pressures will be
correspondingly lower.
3)
Applicable for ratio up to 1 : 10 between backing pump and Roots vacuum pump at 3000 rpm
4)
Authoriative, however, is the oil level at the oil-level glass
5)
After a complete disassembly
6)
At an operating pressure below < 10
-1
mbar (< 0.75 x 10
-1
Torr)
8)
Motor voltage and current may deviate depending on the type of motor.
Please always note the information on the nameplate.
Summary of Contents for RUVAC WA
Page 67: ...Notes 67 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...
Page 68: ...68 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Declaration of Conformity ...
Page 69: ...69 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum EC Incorporation Declaration ...
Page 71: ...Index 71 GA03107_002_A4 09 2015 Oerlikon Leybold Vacuum ...