background image

English 7 English 

 

WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION: Remove fire hazards from the welding area 
and have a fire extinguisher readily available. Welding sparks and hot materials from the welding process 
can easily go through small cracks and openings to adjacent areas. Do not weld on any tanks, drums, 
containers, or material until the proper steps have been taken to insure that no flammable or toxic vapors 
will be present. Never operate this equipment when flammable gases, vapors or liquid combustibles are 
present. 

 

WELDED MATERIALS CAN BURN: Welding generates a large amount of heat. Hot surfaces and 
materials in work area can cause serious burns. Use gloves and pliers when touching or moving materials 
in the work area. 

 

CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct 
shielding gas for the process used and properly operating regulators designed for the gas and pressure 
used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or 
transport gas cylinders with the protection cap removed. Do not allow the electrode, electrode holder, 
work clamp or any other electrically live part to touch a gas cylinder. Gas cylinders must be located away 
from areas where they may be subjected to physical damage or the welding process including sparks and 
heat sources. 

 

SAFETY MARK: This equipment is suitable for supplying power for welding operations carried out in an 
environment with increased hazard of electric shock. 

 
The manufacturer reserves the right to make changes and/or improvements in design without upgrade at the same time the 
operator’s manual. 
 

Summary of Contents for CITOMIG 185MP

Page 1: ...IM3080 11 2022 REV05 CITOMIG 185MP 210MP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland...

Page 2: ...he table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Number Date Where Purchased ENGLISH INDEX Technic...

Page 3: ...rrent Output Voltage GMAW 51 Vdc 100 110A 19 5 Vdc 60 160A 22 Vdc 25 200A 24 Vdc FCAW SS 100 110A 19 5 Vdc 60 160A 22 Vdc 25 200A 24 Vdc SMAW 100 100A 24 Vdc 60 140A 25 6 Vdc 30 160A 26 4 Vdc 210MP 23...

Page 4: ...25A 3 Conductor 2 5mm2 210MP DIMENSION Weight Height Width Length 185MP 17 3 kg 396 mm 246 mm 527 mm 210MP WIRE DIAMETER WIRE FEED SPEED RANGE WFS RANGE Solid wires Aluminum wires Cored wires 185MP 1...

Page 5: ...dition Presence MIG mode X TIG mode STICK mode After 30 minutes of non working Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the...

Page 6: ...process gas usage depends on cross sectional area of the nozzle For commonly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may...

Page 7: ...cesses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The opera...

Page 8: ...electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the electr...

Page 9: ...work area CYLINDER MAY EXPLODE IF DAMAGED Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressur...

Page 10: ...e Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle and Overheating The duty cycle of a welding machine...

Page 11: ...ode and the workpiece 5 WFS Hot Start Control Depending on welding process this knob controls GMAW process Wire feed speed WFS Value in percentage of nominal value wire feed speed SMAW process HOT STA...

Page 12: ...r GMAW FCAW SS 22 Spooled Wire for GMAW FCAW SS The machine does not include a spooled wire 23 Wire Spool Support Maximum 5kg spools Accepts plastic steel and fiber spools onto 51mm spindle 24 Shield...

Page 13: ...English 11 English Table 1 Positive polarity factory setting Table 2 Negative polarity...

Page 14: ...again Adjusting of Force of Pressure Roll Force The pressure arm controls the amount of force the drive rolls exert on the wire Pressure force is adjusted by turning the adjustment nut clockwise to i...

Page 15: ...to be used Consult the wire data for this information Connect output the gas cooled gun to GMAW FCAW SS process to Euro Socket 7 Depending on the using wire connect the work lead 19 to output socket...

Page 16: ...ges the function of the gun s trigger 2 Step trigger operation turns welding on and off in direct response to the trigger Welding process is performed when the gun s trigger is pulled 4 Step mode allo...

Page 17: ...r Procedure of begin welding of GTAW process First turn the machine off Connect GTAW torch to 9 output socket Connect the work lead to 8 output socket Connect the work lead to the welding piece with t...

Page 18: ...on Inductance Select Gas Switch On Output Voltage TIG MMA only Spot Welding Setting Select Wire Type material Switch Off Output Voltage TIG MMA only Spot Timer Select Wire Size diameter Unlock panel S...

Page 19: ...be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is...

Page 20: ...n this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine which contains a picture descriptive part number cross reference REACh...

Page 21: ...de holder to SMAW process 3m W000260684 WELDLINE lead s KIT to SMAW process The electrode holder with lead to SMAW process 3m Work lead 3m KIT 200A 25 3M Lead s KIT to SMAW process The electrode holde...