Hot water storage tanks  

150 – 500

7.1

Enamelled domestic water storage tanks

GB

A

B

C

D

E

F

H

I

J

K

L

150

,

200

,

300

l

4

00

,

500

l

Anode

 4

00

,

500

l

G

H

I

H

4

00

,

500

l

150

,

200

,

300

l

150

,

200

,

300

l

400, 500 l

150, 200, 300 l

anode 400, 500 l

150, 200, 300 l

400, 500 l

150, 200, 300 l

  

 

 

 
 
 
 
 
 
 

 

  

 
 

  
 

 
 

 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 

   

 

 
 
 

[l]   
[-] 

[mm] 
[mm] 
[mm] 
[mm] 

[kg] 

 
 

[-] 

[W] 

 

[l]   
[-] 

 

[bar] / [°C] 

 

[m²]  / [l] 

[bar] / [°C] 

 

A [mm] 
B [mm] 
C [mm] 
D [mm] 

E [mm] 
F [mm] 

G [mm] 
H [mm] 

I [mm] 
J [mm] 

K [mm] 

 

L [mm]

 

150

 

 

154 

B2 

1,020 

500 
610 

1,170 

70 

 
 

A+ 

28 

 

236 

 

10 / 95 

 

1.15 / 7.5 

10 / 130 

 

132 
207 
262 
607 
705 
807 

963 

1,019 

762 

 

292

 

200

 

 

201 

B2 

1,265 

500 
610 

1,375 

80 

 
 

A+ 

31 

 

315 

 

10 / 95 

 

1.15 / 7.5 

10 / 130 

 

132 
227 
405 
627 
725 
927 

1209 

1,264 

910 
689 

 

292

 

300

 

 

294 

B2 

1,750 

500 
610 

1,830 

98 

 
 

A+ 

36 

 

471 

10 

 

10 / 95 

 

1.15 / 7.5 

10 / 130 

 

132 
227 
400 
627 
987 

1,347 

1,694 
1,749 
1,405 
1,145 

 

304

 

400

 

 

411 

B2 

1,725 

600 
710 

1,865 

119 

 
 

A+ 

40 

 

628 

13 

 

10 / 95 

 

1.88 / 12.3 

10 / 130 

 

120 
218 
474 
748 
930 

1,265 
1,575 
1,695 

1,370 

895 

 

300

 

500

 

 

507 

B2 

1,770 

650 
760 

1,925 

150 

 
 

A+ 

43 

 

785 

19 

 

10 / 95 

 

1.88 / 12.3 

10 / 130 

 

127 
217 
481 
747 
967 

1,283 
1,597 
1,731 

1,411 

910 

 

325

  

Hot water storage tanks 

 
 

Real volume according to EN 12897 

Fire protection class of insulation according to DIN 4102-1

 

Total height including insulation 
Diameter without insulation 
Diameter with insulation 
Tilt height 
Weight

 
 

Energy efficiency class according to EU regulation 
no. 812/2013 
Heat retaining loss according to EN 12897 
Output capacity 45 °C  
(storage tanks 65 °C, cold water 10 °C, no reheating) 
Performance factor NL following DIN 4708

 
 

Storage tank pmax / tmax

 
 

Smooth-pipe heat exchanger surface /volume 
Smooth-pipe heat exchanger pmax / tmax

 
 

Cold water connection (R 1") 
Return smooth-pipe heat exchanger (Rp 1") 
Sensor sleeve (Ø 6 mm) 
Flow smooth-pipe heat exchanger (Rp 1") 
Circulation connection (R ¾") 
Sensor sleeve (Ø 6 mm)

 

Hot water connection  (R 1")

 

Anode connection (Rp 1¼")

 

Hot water connection  (R 1")

 

Thermometer (Ø 9 mm)

 

Heating element connection (Rp 1½“ )

 

Service hatch  
(bolt circle Ø 150, 8 x M12)

Summary of Contents for 516005260

Page 1: ...www oeg net Installation and Operating Instructions Enamelled domestic water storage tanks GB...

Page 2: ...list Warranty Disposal Technical data and connections Hot water storage tanks 150 500 Hot water storage tanks 800 2 600 Solar storage tanks 200 500 Solar storage tanks 800 2 260 Heat pump storage tank...

Page 3: ...age tanks 1 GB Solar storage tank 200 500 litres page 29 800 2 250 litres page 30 Built under domestic water storage tank vertical 80 200 litres page 32 Hot water storage tank 150 500 litres page 27 8...

Page 4: ...ed specialists heating contractor contract installation company The high efficiency insulation of storage tanks of up to 1 500 litres is made of vacuum panels embedded in a PU foam jacket By e g prick...

Page 5: ...tructions The screw in immersion heaters are subject to the warranty conditions of the manufacturer The cold water connection of the storage tank is attached to the drinking water network the hot wate...

Page 6: ...to be made additionally in order to prevent a short circuit via the mandatory grounding of the line Pressure shocks water hammers 3 3 When installing fast closing shut off and water tapping valves sol...

Page 7: ...te sted yearly and replaced every two years Optionally maintenance free impressed current anodes of different makes can be retrofitted It is of utmost importance that all magnesium protective anodes...

Page 8: ...for preserving any warranty claims The cleaning is done through the flange aperture The enamelled internal surface prevents limestone formation as far as possible and allows for a quick cleaning of li...

Page 9: ...7400 517807402 517807340 517807355 R1 x 500 33 R1 x 700 33 M8 x 500 33 M8 x 500 40 Hot water storage tank 150 x 200 x 300 x 400 x x 500 x x 800 x x 1000 x x 1500 x x 2250 x x 2600 x x Solar storage ta...

Page 10: ...every two years incl replacement of the flange seal yearly cleaning with a drinking water hardness of over 20 dH The warranty claims expire in case of a breach against 6 Defects Warranty in the GT C o...

Page 11: ...695 1 370 895 300 500 507 B2 1 770 650 760 1 925 150 A 43 785 19 10 95 1 88 12 3 10 130 127 217 481 747 967 1 283 1 597 1 731 1 411 910 325 Hot water storage tanks Real volume according to EN 12897 F...

Page 12: ...torage tank pmax tmax bar C 10 95 10 95 10 95 10 95 10 95 Smooth pipe heat exchanger surface volume m l 2 8 18 3 3 21 3 4 5 29 7 4 9 32 5 9 39 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130...

Page 13: ...height including insulation Diameter without insulation Diameter with insulation Tilt height Weight Energy efficiency class according to EU regulation no 812 2013 Heat retaining loss according to EN...

Page 14: ...14 20 2 6 17 2 8 18 6 2 5 16 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130 10 130 10 130 Cold water connection R 1 A mm 153 153 88 67 Return smooth pipe heat exchanger bottom Rp 1 B mm 258...

Page 15: ...16 4 26 4 5 1 33 6 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130 10 130 Cold water connection R 1 A mm 132 120 127 Return smooth pipe heat exchanger bottom Rp 1 B mm 222 230 211 Sensor sle...

Page 16: ...Performance factor NL following DIN 4708 1 3 1 9 2 5 5 Storage tank pmax tmax bar C 10 95 10 95 10 95 10 95 Smooth pipe heat exchanger surface volume m l 0 53 3 44 1 6 8 1 3 8 5 1 48 9 7 Smooth pipe h...

Page 17: ...F r Ihre Notizen Notes Pour vos notes Voor uw aantekeningen...

Page 18: ...02196723 Free service number Phone 00 800 63 43 66 24 Fax 00 800 63 43 29 24 GB OEG GmbH Industriestra e 1 D 31840 Hess Oldendorf info oeg net www oeg net...

Reviews: