Warranty

5

.0

Technical data  

and connections

7

.0

Disposal

6

.0

OEG GmbH grants a warranty on all supplied parts / products based on OEG’s general 
terms and conditions. 
Prerequisite for any warranty claims on the storage tanks is the compliance with the  
following conditions: 
 
• control of the scope of delivery and its delivery condition. In case of doubt, immediate 

contact / consultation with the delivery company and /or OEG. 

• frostproof installation 
• operation only in closed systems 
• proper installation (see type plate) 
• regular tightness control of the storage tank and all its connections  
• yearly control of the magnesium anode and its replacement every two years 
• cleaning every two years incl. replacement of the flange seal 
• yearly cleaning with a drinking water hardness of over 20° dH 
 
The warranty claims expire in case of a breach against § 6 Defects /  
Warranty in the GT&C of OEG GmbH. 

Disposal of packaging 

Transport and packaging material are reintroduced to the recycling cycles by the  
installation company via local waste disposal and recycling facilities. 
 

Disposal and recycling of products after final decommissioning 

The components and operating materials of OEG storage tanks may not be disposed of 
with domestic waste. They have to be reintroduced to the recycling cycles in compliance 
with the local waste disposal and recycling facilities. If you have any questions regarding 
the individual tank components, contact [email protected] or the OEG hotline with the  
telephone number 00800 63436624.

Enamelled domestic water storage tanks

GB

Summary of Contents for 516005260

Page 1: ...www oeg net Installation and Operating Instructions Enamelled domestic water storage tanks GB...

Page 2: ...list Warranty Disposal Technical data and connections Hot water storage tanks 150 500 Hot water storage tanks 800 2 600 Solar storage tanks 200 500 Solar storage tanks 800 2 260 Heat pump storage tank...

Page 3: ...age tanks 1 GB Solar storage tank 200 500 litres page 29 800 2 250 litres page 30 Built under domestic water storage tank vertical 80 200 litres page 32 Hot water storage tank 150 500 litres page 27 8...

Page 4: ...ed specialists heating contractor contract installation company The high efficiency insulation of storage tanks of up to 1 500 litres is made of vacuum panels embedded in a PU foam jacket By e g prick...

Page 5: ...tructions The screw in immersion heaters are subject to the warranty conditions of the manufacturer The cold water connection of the storage tank is attached to the drinking water network the hot wate...

Page 6: ...to be made additionally in order to prevent a short circuit via the mandatory grounding of the line Pressure shocks water hammers 3 3 When installing fast closing shut off and water tapping valves sol...

Page 7: ...te sted yearly and replaced every two years Optionally maintenance free impressed current anodes of different makes can be retrofitted It is of utmost importance that all magnesium protective anodes...

Page 8: ...for preserving any warranty claims The cleaning is done through the flange aperture The enamelled internal surface prevents limestone formation as far as possible and allows for a quick cleaning of li...

Page 9: ...7400 517807402 517807340 517807355 R1 x 500 33 R1 x 700 33 M8 x 500 33 M8 x 500 40 Hot water storage tank 150 x 200 x 300 x 400 x x 500 x x 800 x x 1000 x x 1500 x x 2250 x x 2600 x x Solar storage ta...

Page 10: ...every two years incl replacement of the flange seal yearly cleaning with a drinking water hardness of over 20 dH The warranty claims expire in case of a breach against 6 Defects Warranty in the GT C o...

Page 11: ...695 1 370 895 300 500 507 B2 1 770 650 760 1 925 150 A 43 785 19 10 95 1 88 12 3 10 130 127 217 481 747 967 1 283 1 597 1 731 1 411 910 325 Hot water storage tanks Real volume according to EN 12897 F...

Page 12: ...torage tank pmax tmax bar C 10 95 10 95 10 95 10 95 10 95 Smooth pipe heat exchanger surface volume m l 2 8 18 3 3 21 3 4 5 29 7 4 9 32 5 9 39 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130...

Page 13: ...height including insulation Diameter without insulation Diameter with insulation Tilt height Weight Energy efficiency class according to EU regulation no 812 2013 Heat retaining loss according to EN...

Page 14: ...14 20 2 6 17 2 8 18 6 2 5 16 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130 10 130 10 130 Cold water connection R 1 A mm 153 153 88 67 Return smooth pipe heat exchanger bottom Rp 1 B mm 258...

Page 15: ...16 4 26 4 5 1 33 6 Smooth pipe heat exchanger pmax tmax bar C 10 130 10 130 10 130 Cold water connection R 1 A mm 132 120 127 Return smooth pipe heat exchanger bottom Rp 1 B mm 222 230 211 Sensor sle...

Page 16: ...Performance factor NL following DIN 4708 1 3 1 9 2 5 5 Storage tank pmax tmax bar C 10 95 10 95 10 95 10 95 Smooth pipe heat exchanger surface volume m l 0 53 3 44 1 6 8 1 3 8 5 1 48 9 7 Smooth pipe h...

Page 17: ...F r Ihre Notizen Notes Pour vos notes Voor uw aantekeningen...

Page 18: ...02196723 Free service number Phone 00 800 63 43 66 24 Fax 00 800 63 43 29 24 GB OEG GmbH Industriestra e 1 D 31840 Hess Oldendorf info oeg net www oeg net...

Reviews: