168
TECHNICAL INFORMATION
The values spec
ifi
ed in the catalog correspond to SAE AS 13441:2004 method 3001.1. The table values were
determined according to EIA 364-20E:2015. The inserts were tested while mated, and the test current was applied
to the pin insert.
75 % of the dielectric withstanding voltage is used for the further calculation. The operating voltage is 1/3 of this value.
All tests were conducted at normal indoor climate and apply up to an altitude of 2,000 m. If there are any
deviations, the reduction factors are to be factored in according to the applicable standards. Test voltage:
Dielectric withstanding voltage × 0.75 Operating voltage: Dielectric withstanding voltage × 0.75 × 0.33
ATTENTION:
With certain applications, the safety requirements for electrical devices are very strict in terms of operating volt-
age. In such cases, the operating voltage is defi ed according to the clearance and creepage distances between
parts which could be touched.
When selecting such a connector, please contact us and let us know the safety standard which the product must meet.
Test voltage: Dielectric withstanding voltage × 0.75
Operating voltage: Dielectric withstanding voltage × 0.75 × 0.33
OPERATING VOLTAGE
Acc. SAE AS 13441:2004 method 3001.1
Summary of Contents for MINI-SNAP K Series
Page 10: ...ODU MINI SNAP Table of Contents...
Page 16: ...ODU MINI SNAP Table of Contents...
Page 17: ...CONFIGURATION GUIDELINE Correct configuring step by step CONFIGURATION Table of Contents...
Page 22: ...ODU MINI SNAP Table of Contents...
Page 37: ...89 SERIES K SERIES K FOR YOUR NOTES Table of Contents...
Page 55: ...107 SERIES K SERIES K FOR YOUR NOTES Table of Contents...
Page 61: ...113 SERIES K SERIES K FOR YOUR NOTES Table of Contents...
Page 62: ...ODU MINI SNAP Table of Contents...