Assembly Straight Plug Size 2
1. Slide back nut and cable collet
over the cable.
2. Strip cable and wire (see page 10).
3. Pre-tinning of strands.
4. Solder the litz wires (A) according
to contact arrangement.
Recommended cleaning agent:
Isopropyl Alcohol.
010.013.005.000.000
Assembly Instructions
Housing
Cable collet
Back nut for
cable bend relief
(style 4)
Cable bend relief
Back nut (style 1)
Insert with
solder capacity