Summary of Contents for Nways 2216

Page 1: ...2216 Nways Multiaccess Connector Installation and Initial Configuration Guide GA27 4106 01...

Page 2: ......

Page 3: ...2216 Nways Multiaccess Connector Installation and Initial Configuration Guide GA27 4106 01...

Page 4: ...he back of this publication If the form has been removed address your comments to Department CGF Design Information Development IBM Corporation PO Box 12195 RESEARCH TRIANGLE PARK NC 27709 9990 USA Wh...

Page 5: ...g an ASCII Terminal 3 3 ASCII Terminal Setup Attributes 3 3 Managing the Operational and Configuration Software 3 5 Chapter 4 Performing the Initial Configuration 4 1 Setting Up the Router Initial Con...

Page 6: ...iv 2216 Installation and Initial Configuration Guide...

Page 7: ...device The Configuration Program for IBM 2216 Nways Multiprotocol Access Services Configuration Program a graphical user interface that allows you to configure the device from a stand alone workstatio...

Page 8: ...dd Device command See Adding an Adapter at Initial Configuration on page B 4 for information on using the Add Device command 5 Run the Quick Configuration program to perform the initial configuration...

Page 9: ...Common Tasks and the IBM 2216 Library About This Guide vii...

Page 10: ...6 2216 Nways Multiaccess Connector Installation and Initial Configuration Guide This booklet explains how to install the IBM 2216 and verify its installation GX27 3988 2216 Nways Multiaccess Connector...

Page 11: ...SC30 3885 Nways Multiprotocol Access Services Protocol Configuration and Monitoring Reference Volume 2 These books describe how to access and use the Nways Multiprotocol Access Services command line...

Page 12: ...s This page provides information on engineering changes clarifications and fixes that were implemented after the books were printed http www networking ibm com 216 216lib html relnts x 2216 Installati...

Page 13: ...289 HSSI LIC 288 10 100 Mbps Ethernet LIC 287 ESCON Channel from Release 1 1 LIC 294 high performance 155 Mbps ATM multimode fiber MMF LIC 295 high performance 155 Mbps ATM single mode fiber SMF Syste...

Page 14: ...xii 2216 Installation and Initial Configuration Guide...

Page 15: ...First SD21 0030 IBM 2216 Planning Guide GA27 4105 IBM 2216 Maintenance Guide SY27 0350 IBM 2216 Hardware Configuration Quick Reference Card GX27 3988 Configuration Program User s Guide GC30 3830 Hardw...

Page 16: ...as required Continue with step 9 on page 1 4 3 Rack Mounting To make the IBM 2216 easier to lift remove 1 The fan tray 2 Each power supply To remove them loosen the screws on each component and pull t...

Page 17: ...the brackets are fitted correctly the letter embossed on each bracket is in the top rear corner an A on the right side and a B on the left side 5 Rack Mounting The installation aid is a metal bar tha...

Page 18: ...Mounting 1 3 2 4 Install the pairs of screws in the order shown 8 Rack Mounting Reinstall the fan tray and each power supply making sure the screws are secured If the power supply resists shift it to...

Page 19: ...em Card Status on page 2 3 3 Ensure that the Hardware Configuration Quick Reference card is completed and placed in the area provided under the IBM 2216 on the left 11 Complete the Setup Rack or Surfa...

Page 20: ...1 6 2216 Installation and Initial Configuration Guide...

Page 21: ...ower supply If the problem is not corrected contact your service representative No Go to the next question On the system card is the top green LED off Yes The green LED is switched on by the operation...

Page 22: ...Yellow Overcurrent On There is an overcurrent condition with the 48 V to one or more of the adapters slots 1 8 or the 12 V to the fan tray Green DC On 5 V 12 V and 48 V are OK Green AC On AC source vo...

Page 23: ...gged into the 2216 violates the plugging rules described in Appendix A Factory Plugging Defaults on page A 1 Green port1 On Port is operating normally enabled and configured Off Port is not configured...

Page 24: ...2 4 2216 Installation and Initial Configuration Guide...

Page 25: ...You can set up both a local and a remote connection to the IBM 2216 However only one port can be active at any given time If a workstation is connected locally to the serial port and a call comes in...

Page 26: ...on or TTY Figure 3 1 Remote Serial Connection to the PCMCIA Modem 2216 B Null Modem Adapter 10H5570 EIA 232 Workstation with SLIP Connection or TTY Figure 3 2 Local Serial Connection to the EIA 232 Po...

Page 27: ...iate emulation software to provide local or remote access to the 2216 as shown in Figure 3 1 on page 3 2 and Figure 3 2 on page 3 2 The DEC VT100 ASCII terminal is supported as well as devices such as...

Page 28: ...ent Request to Send 2 Terminal emulators that require a terminal type selection should be set to VT 220 Function Keys Function 1 F1 Esc O P Hex 1B 4F 50 Function 2 F2 Esc O Q Hex 1B 4F 51 Function 3 F...

Page 29: ...storing two copies of its operational software and four copies of configuration information for each copy of the operational software Without interrupting the operation of the IBM 2216 you can store s...

Page 30: ...3 6 2216 Installation and Initial Configuration Guide...

Page 31: ...Configuration program 3 Perform an initial configuration to establish the IP address and IP mask for the primary LAN interface for the router as follows a Configure Bridging 1 Enter No to Configure Br...

Page 32: ...may need to modify the configuration that you have created using QCONFIG to customize the IBM 2216 to work on your network You can do this using either of these methods Configuration Program The Conf...

Page 33: ...at can be dynamically altered For more information about the command line interface refer to the Software User s Guide Use the Configuration Program User s Guide in order to create a complete configur...

Page 34: ...4 4 2216 Installation and Initial Configuration Guide...

Page 35: ...llation for the various adapters FC 2280 and FC 2281 are installed left to right beginning with slot 1 A maximum of six can be installed in any single IBM 2216 Other adapters are installed right to le...

Page 36: ...r ESCON adapters FC 2287 Two ATM adapters FC 2284 or FC 2293 Four ISDN adapters FC 2283 or FC 2292 Any adapter can be installed in any of the eight adapter slots with the following restrictions 1 If t...

Page 37: ...m cable for local access or a modem attachment for remote access See Chapter 3 Accessing the 2216 on page 3 1 for more information Command Line Interface Question How do I access the command line inte...

Page 38: ...and Line Interface with the protocol command as an example Displaying List of Configured Interfaces Question How do I display a list of active interfaces Answer 1 Access the command line interface the...

Page 39: ...the prompt 2 Type talk 5 and press Enter twice to reach the prompt 3 Type protocol and press Enter 4 Type ip and press Enter The prompt changes to IP 5 Type ping IP address value and press Enter Press...

Page 40: ...y installed it does not have any software configuration The operating system will put you at the Config only prompt 1 Enter add device type of device Note The steps only create the interface You still...

Page 41: ...device to see a list of device choices The following two steps do not apply when a dial circuit device is being added 4 Enter the device slot number 1 8 5 If you are adding an interface on a single p...

Page 42: ...ke a note of the interface number of the adapter you wish to disable 5 Enter disable interface interface number 6 Enter write to save your changes The next time that the 2216 is rebooted the configura...

Page 43: ...ng the talk 5 disable command in Suspend Traffic on an Adapter Port to resume traffic Answer 1 Access the command line interface prompt 2 Type talk 5 and press Enter twice to reach the prompt 3 Enter...

Page 44: ...pter 5 Enter delete interface interface number 6 At the Are you sure prompt enter y 7 Enter write to save your changes 8 Reboot the IBM 2216 to make the configuration changes active For details of thi...

Page 45: ...matically enable an alternate interface that is on an adapter that has be replaced Answer 1 Access the command line interface the prompt 2 Type talk 5 and press Enter twice to reach the monitoring pro...

Page 46: ...to remotely connect to the 2216 5 Dial in to the 2216 s PCMCIA modem with a TTY console The console settings must be Speed 19200 bps Data bits 8 Parity No Stop bits 1 6 Once the connection is establis...

Page 47: ...ilities menu and select 11 Remote Initial Program Load Setup before a TFTP can be done a Select 10 TFTP software from the Change Management Software Control menu b Select 1 Config from the Select Type...

Page 48: ...B 12 2216 Installation and Initial Configuration Guide...

Page 49: ...ment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in...

Page 50: ...sed in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CISPR22 Compliance Statement This product has been tested and fou...

Page 51: ...escheinigung laut dem Deutschen Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG vom 30 August 1995 bzw der EMC EG Richlinie 89 336 Dieses Ger t ist berechtigt in bereinstimmung mit...

Page 52: ...be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your e...

Page 53: ...entreprise de t l communications L installation de cet quipement doit aussi se faire selon un mode de raccordement acceptable Dans certains cas le c blage interne de l entreprise associ au service in...

Page 54: ...34 J 100003 for indirect connections to the public telecommunications systems in the United Kingdom Trademarks The following terms are trademarks of the IBM Corporation in the United States or other c...

Page 55: ...oe u electrische apparatuur op een veilige manier moet bekabelen en aansluiten Danger Avant de proc der l installation de ce produit lisez d abord les consignes de s curit dans la brochure ATTENTION C...

Page 56: ...crit les proc dures respecter pour effectuer les op rations de c blage et brancher les quipements lectriques en toute s curit Vorsicht Bevor mit der Installation des Produktes begonnen wird die Siche...

Page 57: ...m beskriver sikkerhetsrutinene for kabling og tilkobling av elektrisk utstyr Perigo Antes de iniciar a instala o deste produto leia as informa es de seguran a Cuidado Informa es de Seguran a Leia Prim...

Page 58: ...ibe los procedimientos de seguridad para cablear y enchufar equipos el ctricos Varning livsfara Innan du b rjar installera den h r produkten b r du l sa s kerhetsinformationen i dokumentet Varning S k...

Page 59: ...a 43 1 kg ATTENTION Un IBM 2216 enti rement quip p se environ 43 1 kg ACHTUNG Eine voll best ckte IBM 2216 wiegt ungef hr 43 1 kg ATTENZIONE Un IBM 2216 cui sono collegate tutte le unit pesa circa 43...

Page 60: ...UWAGA Ca kowicie wype nione urz dzenie IBM 2216 wa y oko o 43 1 kg D 6 2216 Installation and Initial Configuration Guide...

Page 61: ...help ix http site ix I initial configuration 4 1 Installing the 2216 1 1 M managing configuration problems 4 2 methods of access 3 1 P performing the initial configuration 4 1 physical access methods...

Page 62: ......

Page 63: ...stage free or fax it to us at 1 800 253 3520 Elsewhere your local IBM branch office or representative will forward your comments or you may mail them directly to us Specific comments or problems Pleas...

Page 64: ...CESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 40 ARMONK NEW YORK POSTAGE WILL BE PAID BY ADDRESSEE Design Information Development Dept CGF Bldg 656 Internationa...

Page 65: ......

Page 66: ...Part Number 02L1814 Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber 02L1814 GA27 4106 01...