INSTALLATION
How To Install Your OdorStop UV Air Treatment System
If your heating/cooling (HVAC) system is equipped with air
conditioning, it is recommended that the UV Air Treatment
System (unit) be mounted directly above the cooling coil. The
OS36/OS72 can prevent the growth of a high percentage
of micro-organisms such as mold, bacteria, and viruses on
surfaces such as cooling coils, drain pans, and duct work.
Selecting Mounting Location
1. If heating/cooling (HVAC) system is equipped with air
conditioning, it is recommended that the UV Air Treatment
System be mounted directly above the cooling coil (“A
Coil”).
2. The unit can be mounted in any orientation, but should be
mounted in a way that the LED indicator light(s) can be seen.
3. Choose a location that will make changing/cleaning of the
UV bulb(s) easy.
4. Install unit on a flat surface of the duct work ABOVE the air
conditioning cooling coil (“A Coil”) if your HVAC system has
air conditioning. If your HVAC system does not have air
conditioning, the unit should be installed on the supply air
duct if possible. The unit can be installed on a return air duct
if necessary.
CAUTION: DO NOT install the unit in the “A coil” or under
a humidifier as damage may occur. If you are unsure if you
have chosen a correct mounting location, refer to your
HVAC system’s owners manual or call a qualified professional for assistance.
5. Select a mounting location that has a minimum depth of 17 inches if installing a system with 16” bulbs
and 13 inches for a system with 12” bulbs.
6. Be sure to locate the unit away from any plastic or rubber components that may be damaged by UV
light. If mounting options are limited, plastic and rubber may be covered with aluminum foil tape to
protect them from the UV light.
7. The unit has a 6 foot long power cord and must be installed within reach of a 120 Volt grounded power
outlet. Have a qualified professional install a properly grounded power outlet if there is not one within
range of the power cord.
Included:
• UV System
• 8 Sheet Metal Mounting Screws
• UV Bulb(s)-1 for OS36,
2 for OS72, 4 for OS144
• Spare Fuse
• Instruction Manual
Tools Required For Installation:
• Drill
• 1/8” Drill Bit
• 1/4” Nut Driver
• Tin Snips
• 2 1/2” Metal Cutting Hole Saw