background image

13. Turn the system on (solid line on the switch pressed down) and verify 

that the LED indicator light(s) are illuminated.  

 

NOTE: The system will not turn on unless air is moving in the duct. 

If green LED light(s) are not illuminated, see troubleshooting section. 

UV air treatment system is now operational and does not need to be 

powered off unless it needs to be serviced.

14. After 24 hours, set the fan switch on the thermostatm into “AUTO” 

mode. The system is now operational and will only turn on when air 

flow is detected. 

NEVER LOOK DIRECTLY AT OR TOUCH A UV BULB WHILE ILLUMINATED.

Maintaining Your UV Air Treatment System   

 

 

 

 

In order to keep your system operating at maximum effectiveness, it is recommended that you clean the 

UV bulb(s) every 3 months and replace every year.

Bulb 

Cleaning 

and 

Replacement 

      

1. Turn the power to HVAC system off, unplug UV system, and allow UV bulb(s) to cool for at least 15 

minutes before attempting to remove UV system.

2. Remove 8 sheet metal screws and slide UV system out of duct work.  
3a. To Clean: Hold the UV system securely and wipe the UV bulb(s) with a soft cloth dampened with glass 

cleaner.  If you touch the glass with your hand, be sure to wipe away any fingerprints or dirt with cloth. 

Make sure bulb is clean and dry before installing system back into duct.

3b. To Replace: Visit www.OdorStop.com to purchase new UV bulbs if needed.  Use of any bulb not 

approved for system by OdorStop will void the warranty and could cause damage to system or 

serious injury.  Hold the UV system securely and push the bulb release button(s) to remove the UV 

bulb(s).  Install new bulb(s) in system by sliding the bulb(s) in from the inside until bulb snaps into 

place.  If you touch the glass with your hand, be sure to wipe away any fingerprints or dirt with a soft 

damp cloth. Make sure bulb(s) is clean and dry before installing system back into duct.  

6

Summary of Contents for OS144PRO

Page 1: ...low sensor and must be installed in the HVAC system in an area that has sufficient airflow to activate the sensor Please contact our customer care department with any questions service odorstop com 1...

Page 2: ...16 648 6406 www OdorStop com Purchase Date _____________________________________________ Serial Number ______________________________________________ Purchased From ___________________________________...

Page 3: ...and can cause personal injury Wear protective gloves when handling bulb s and installing bulbs into system base System should be turned off at least 15 minutes before removing UV bulb s Bulbs contain...

Page 4: ...hould be installed on the supply air duct if possible The unit can be installed on a return air duct if necessary CAUTION DO NOT install the unit in the A coil or under a humidifier as damage may occu...

Page 5: ...system 2 Select the correct template and tape it to the duct work in the intended installation position 3 For OS36 and OS72 Pre drill two 2 1 8 holes where indicated For OS144 Pre drill four 4 1 8 ho...

Page 6: ...negatively affect its operation 6 Use tin snips to cut out the metal ducting between the drilled holes along dotted lines as shown in step 5 7 Install bulb s by sliding them in from the inside until b...

Page 7: ...e an extension cord 11 Turn the power to the HVAC system on 12 Set the fan switch on the thermostat to the ON position NOTE It is recommended that the system be run continuously for at least 24 hours...

Page 8: ...m off unplug UV system and allow UV bulb s to cool for at least 15 minutes before attempting to remove UV system 2 Remove 8 sheet metal screws and slide UV system out of duct work 3a To Clean Hold the...

Page 9: ...air moving through the system turn system on The bulb s is are faulty replace bulb s The fuse on the system is faulty replace the fuse Insufficient airflow to activate the airflow sensor The lead for...

Page 10: ...CE PROTECTION AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT OdorStop UV Air Treatment System OS36PRO INSTALLATION TEMPLATE STEP 1 TAPE TEMPLATE TO DUCTWORK STEP 2 DRILL HOLES WITH 2 1 2 HOL...

Page 11: ...CE PROTECTION AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT OdorStop UV Air Treatment System OS72PRO INSTALLATION TEMPLATE STEP 1 TAPE TEMPLATE TO DUCTWORK STEP 2 DRILL HOLES WITH 2 1 2 HOL...

Page 12: ...E PROTECTION AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT OdorStop UV Air Treatment System OS144PRO INSTALLATION TEMPLATE STEP 1 TAPE TEMPLATE TO DUCTWORK STEP 2 DRILL HOLES WITH 2 1 2 HOL...

Reviews: