OCULUS Access XL E Series Instructions Installation & Operation Download Page 5

Section 6 -

 Operation

 CAUTION:

 When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary.

•  110-120V SINGLE STATION CONTROL -

 3-position UP-OFF-DOWN switch permits operation to be stopped at any point. Factory adjusted limit switches 

automatically stop screen when fully down or fully up.

•  24V CONTROL -

 3-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop 

screen when fully up or fully down. Installer should incorporate an all-pole disconnect in fixed wiring available with RF or IR remote.

•  RS232 / ETHERNET -

 Serial communication and network communication optionally available.

•  KEY OPERATED SWITCHING -

 Two key-operated switches optionally available with this unit:

• 

Key-operated power supply switch controls power to screen and switches. When “off”, switches will not operate screen. Key may be removed from switch in 

either "on" or "off" position.

• 

3-position key switch permits the screen to be operated directly by key. Requires screen operator to have a key.

Section 7 -

 Tab-Tension Adjustment Procedure

Please Note:

 Draper Tab-Tensioning System is factory-set, and under normal 

circumstances will not require field adjustments. If wrinkles are observed, follow the 

adjustment procedure shown in Fig. 8.

PUSH & TURN

CLOCKWISE

to INCREASE TENSION

PUSH & TURN

COUNTER-CLOCKWISE

to RELEASE TENSION

END OF 
DOWEL

END OF 
DOWEL

Figure 8

page 5 of 8

Access XL E and V

Summary of Contents for Access XL E Series

Page 1: ...ut Tab Tensioning V Dowel E Dowel Mounting Bracket Mounting Bracket Hoisting Bracket Leveling Brackets Hoisting Bracket E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface Trim Flange Shipping Brackets Attached to Dowel and Screen Case V Screens Only Please Note Shipping brackets must remain in place until product has been mounted and connected to power see Sections 1 and 4 in this doc...

Page 2: ...safety concerns including nearby persons or objects 11 After installation the entire system including all sensors should be carefully tested to ensure safe and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and ...

Page 3: ...uate strength and suitable for the mounting surface chosen Supporting hardware such as chains cables two 3 8 9 5 mm rods etc must be precisely vertical 4 Entire bottom of case must be readily accessible after installation is complete 5 Front back and top of case must be straight not forced to warp or bow CAUTION Screen case and flange are not designed to serve as ceiling support 6 Do not seal unit...

Page 4: ...ded make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end of roller and slide mounting bracket toward roller Insert roller pin into nylon bushing on idler bracket Fig 6 8 Roller idler pin goes through idler bracket Reinstall washer and retaining clip Caution Failure to replace washer and retaining clip could result in separatio...

Page 5: ...e RS232 ETHERNET Serial communication and network communication optionally available KEY OPERATED SWITCHING Two key operated switches optionally available with this unit Key operated power supply switch controls power to screen and switches When off switches will not operate screen Key may be removed from switch in either on or off position 3 position key switch permits the screen to be operated d...

Page 6: ...s 5 32 4 mm Hex key To Reduce Screen Drop 1 Raise screen surface approximately 1 30 cm above desired setting and turn off 2 Turn DOWN I limit screw clockwise 3 screw turns 1 2 roller revolution 3 Test by lowering screen Repeat steps 1 2 until desired position is reached To Increase Screen Drop 1 Lower screen to down limit 2 With down switch on turn DOWN I limit screw counterclockwise 3 screw turns...

Page 7: ...andard Motor Wiring is on the AUDIENCE LEFT END of Screen Case R 5mm 2 73mm 3 92mm 3 92mm 8 225mm 10 257mm 2 73mm 2 73mm 11mm 1 38mm 3 mm 6mm 6 mm TYP 19mm TYP 13mm 13mm 13mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below Leveling bracket is used to level the case...

Page 8: ... others IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yellow to 110V 120V AC Hot Black to 110V 120V AC Hot White Common to screen 110V 120V AC ...

Reviews: