background image

Remove 

fasteners from 

bracket clamps.

Run screen

DOWN to expose 

dowel screws. 

Loosen screws  

and remove 

shipping bracket.

Retighten 

dowel endcap 

screws.

 WARNING   

Improper installation and use of the Access XL E & V screen can result in serious injury or death. Primarily, injuries can occur if the unit falls due to  

imprecise installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure. Please use extreme care.
1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and could 

result in serious injury.

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical 

work and wiring [indicated in diagram by dashed lines] must be completed only 

by a qualified professional electrician who has read this manual completely 

and is familiar with the construction and operation of this equipment and the 

hazards involved.

3. 

Do not affix the unit to walls or ceilings that have inadequate strength 

to permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all 

times. Draper

®

, Inc., is not responsible for improper installation, application, 

testing, or workmanship related to the product at place of installation.

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used 

for mounting.

5. 

All hardware must be installed level. Unit must be level and square.

6. 

Never leave the area while operating the unit during installation, maintenance, 

or normal operation, unless it is secure and safe.

7. 

Before testing or operation, carefully inspect the entire area and path 

(especially 

underneath)

 of unit to be sure no persons or objects are in the area.

8. 

Turn off power and any nearby equipment or cables carrying electricity before 

connecting switches, wires, controls, or electrical components.

9. 

Do not wire motors in parallel without written permission from Draper, Inc.

10. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects.

11. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury.

12. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in its safe and effective operation and 

understand its safety features.

13. 

The safety features of the unit should never be disabled, bypassed, or 

overridden. The system should not be operated until all safety features are 

properly and completely installed, calibrated, and tested.

14. 

Unit may need to comply with local, state, or district rules and regulations, in 

particular when installed in schools. All applicable rules and regulations should 

be reviewed before installation and use.

15. 

Failure to precisely follow installation guidelines invalidates all warranties.

16. 

Custom products/installations may not be reflected in this manual. Call Draper, 

Inc., if you have questions about the installation of custom products or any 

questions about your installation.

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or 

operation of the system.

2. 

Read carefully and be sure to understand all installation instructions and 

all related operations manuals. These instructions are intended to serve 

as a guide for the installer and owner. They should be followed closely and 

combined with the expertise of experienced qualified installers. Draper, Inc.,  

is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. Please retain all 

instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper unit and parts. 

Controls may be shipped separately, or in same carton as unit.

6. 

If you have any difficulties with installing, servicing, or operating your unit, call 

your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Safety Information

Section 1 -

  Removing Shipping Brackets 

(Tab-Tensioned, "V" Surfaces only)

 CAUTION:

 DO NOT remove shipping 

brackets until product has been 

mounted and connected to power 

(see 

Section 4 in this document.)

.  

Also, DO NOT OPERATE SCREEN 

BEFORE REMOVING SHIPPING 

BRACKETS FROM SCREEN CASE.

page 2 of 8

Access XL E and V

Summary of Contents for Access XL E Series

Page 1: ...ut Tab Tensioning V Dowel E Dowel Mounting Bracket Mounting Bracket Hoisting Bracket Leveling Brackets Hoisting Bracket E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface Trim Flange Shipping Brackets Attached to Dowel and Screen Case V Screens Only Please Note Shipping brackets must remain in place until product has been mounted and connected to power see Sections 1 and 4 in this doc...

Page 2: ...safety concerns including nearby persons or objects 11 After installation the entire system including all sensors should be carefully tested to ensure safe and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and ...

Page 3: ...uate strength and suitable for the mounting surface chosen Supporting hardware such as chains cables two 3 8 9 5 mm rods etc must be precisely vertical 4 Entire bottom of case must be readily accessible after installation is complete 5 Front back and top of case must be straight not forced to warp or bow CAUTION Screen case and flange are not designed to serve as ceiling support 6 Do not seal unit...

Page 4: ...ded make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end of roller and slide mounting bracket toward roller Insert roller pin into nylon bushing on idler bracket Fig 6 8 Roller idler pin goes through idler bracket Reinstall washer and retaining clip Caution Failure to replace washer and retaining clip could result in separatio...

Page 5: ...e RS232 ETHERNET Serial communication and network communication optionally available KEY OPERATED SWITCHING Two key operated switches optionally available with this unit Key operated power supply switch controls power to screen and switches When off switches will not operate screen Key may be removed from switch in either on or off position 3 position key switch permits the screen to be operated d...

Page 6: ...s 5 32 4 mm Hex key To Reduce Screen Drop 1 Raise screen surface approximately 1 30 cm above desired setting and turn off 2 Turn DOWN I limit screw clockwise 3 screw turns 1 2 roller revolution 3 Test by lowering screen Repeat steps 1 2 until desired position is reached To Increase Screen Drop 1 Lower screen to down limit 2 With down switch on turn DOWN I limit screw counterclockwise 3 screw turns...

Page 7: ...andard Motor Wiring is on the AUDIENCE LEFT END of Screen Case R 5mm 2 73mm 3 92mm 3 92mm 8 225mm 10 257mm 2 73mm 2 73mm 11mm 1 38mm 3 mm 6mm 6 mm TYP 19mm TYP 13mm 13mm 13mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below Leveling bracket is used to level the case...

Page 8: ... others IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yellow to 110V 120V AC Hot Black to 110V 120V AC Hot White Common to screen 110V 120V AC ...

Reviews: