38
12. OPTION BLACK BOX AND SUPER BLACK BOX
12.2. Super Black Box option
Operation
Blue power LED
The blue "power" LED illuminates when the power amplifier (or integrated amplifier) is
switched on via the amplifier's power on/off switch.
Yellow unload LED
The yellow "unload" LED (discharge control circuit) illuminates for approximately two
seconds after switch-off, and also when the electronic protection is activated and when
the V 80 SE is powered down with Ecomode on. The Super Black Box is equipped with a
rapid discharge circuit, which discharges the unit's electrolytic. The yellow LED indicates
that this procedure is taking place. The discharge circuit is also activated if the SBB
connecting cable is accidentally removed. This is to prevent the SBB maintaining its
charge when it has not been properly disconnected.
Specifications
Dimensions
203 X 150 X 330 mm (W x H x D)
Weight 5.6
kg
Connection cable
Length: 90 cm. Longer cables upon request.
Connecting to the amplifier
(Please see Black Box option)
Summary of Contents for V 80 SE
Page 1: ...V 80 SE Owner s Manual English ...
Page 14: ...15 3 GETTING STARTED 3 7 Connection possibilities overview ...