7. TYPICAL APPLICATIONS

Application Circuit 1: Single color (DC plug 2.1/5.5)

8. ABOUT RF CODE

The biggest advantage of this system is that it can not only solve the cabling problem in engineering wireless-
ly, but also realize a wired-like operation experience. In order to facilitate the early testing and debugging of 
the project, the factory status of the receiver is normally unpaired and each remote controller has a unique 
code value. The user should perform the matching work of the remote controller and the receiver during 
the installation of the project to avoid the mutual influence of the radio frequency remote control technology 
during the later use.

Please pay attention to the following 3 points before operation:

   All equipment in the complete system after installation should have a unified and unique code value, so    

 

as to achieve the security and stability of the system.

   The receiver can only store one code value and cannot be overwritten. Before learning the new code  

 

 

value, it is necessary to clear the original code of the receiver; the remote controller can only save one    

 

code value but can be overwritten and can also restore the factory settings. In order to facilitate the later    

 

maintenance, the three components that may be involved in the system (including receivers, handheld    

 

remote controllers, and panel remote controllers) can realize mutual learning of code values.

   Since the receiver performs code value learning in the power-on state, batch-operation is available  

 

(power-one the all receivers which will be in same zone, and operate the matching/clearing the RF code    

 

all of them at the same time)

. And in order to avoid confusion in the area, it is recommended that each    

 

area has an independent power switch so that the power of other areas can be easily cut off when  

 

 

the code is being operated.

M 1497-4 DIMMER FOR WALLWASHER

User Manual M-OWP 1.1

Summary of Contents for M 1497-4

Page 1: ... Adopts RF remote control no need line of sight Wireless sync control in both static color and dynamic modes unlimited by remote control distance Batch operation is available for RF code matching clearing between remote control and receivers Memory function each time power on reserve the mode which stop in the last power off Perfect control effect soft dim function Long press the brightness and sp...

Page 2: ...or each other so multiple receivers in same zone will wireless sync work completely not only static mode but also dynamic mode to achieve wired like operation experience T 4971177003 0 F 4971177003 53 info octanorm de www octanorm com OCTANORM Germany Head Office Raiffeisenstraße 39 70794 Filderstadt Input port DC plug 2 1 5 5 Output port DC plug for DIM M 1497 4 DIMMER FOR WALLWASHER User Manual ...

Page 3: ...n 20 seconds the touch remote will enter the sleep state please SHAKE the remote to wake up it before the next using NAME OF KEY INSTRUCTION REMARKS Off Off in any time On On in any time Mode The mode will go to next when you touch the key each time 2 modes in total fade or flash speed is adjustable brightness is unadjustable Speed Brightness The speed brightness will 1 when you touch the key each...

Page 4: ...er installation should have a unified and unique code value so as to achieve the security and stability of the system The receiver can only store one code value and cannot be overwritten Before learning the new code value it is necessary to clear the original code of the receiver the remote controller can only save one code value but can be overwritten and can also restore the factory settings In ...

Page 5: ...ill automatically exit code transmission status after 60 seconds or pressing any key to exit 3 See the load light flashes 3 times and return to the initial state 2 modes in total fade or flash speed is adjusta ble brightness is unadjustable STEP OPERATION INSTRUCTIONS 1 Connecting the load to the receiver and power on it 1 The clearing operation should be finished within 1 minute after the receive...

Page 6: ...nsmitted for a maximum of 30 seconds please release it and operate again if times out STEP OPERATION INSTRUCTIONS 1 A remote control Press and hold ON on the remote control for 5 seconds the indicator of the remote control will flash quickly means it enters the pairing code transmission status Will automatically exit code transmission status after 60 seconds or pressing any key to exit 2 B remote ...