![Octagon 5554 User Manual Download Page 29](http://html.mh-extra.com/html/octagon/5554/5554_user-manual_723598029.webp)
Technical Data – 21
CHAPTER 4
TECHNICAL DATA
TECHNICAL SPECIFICATIONS
Environmental
–40° to 85° C operating
–50° to 90° C nonoperating
RH 5% to 95%, noncondensing
Power Specification
5554: 5V +/– 5% at 80 mA max.
5558: 5V +/– 5% at 150 mA max.
Size
4.5 in. x 4.9 in.
I/O Map
5554/5558 I/O Map
Serial
Card
Port
W4
[1-2][3-4]
W4
[1-2]
W4
[3-4]
W4
None
Base=100H
Base=140H
Base=180H
Base=1C0H
5558
Octal
Port 1
100
140
180
1C0
Port 2
108
148
188
1C8
Port 3
110
150
190
1D0
Port 4
118
158
198
1D8
Port 5
120
160
1A0
1E0
Port 6
128
168
1A8
1E8
Port 7
130
170
1B0
1F0
Port 8
138
178
1B8
1F8
5554
Quad
Port 1
100
140
180
1C0
Port 2
108
148
188
1C8
Port 3
110
150
190
1D0
Port 4
118
158
198
1D8
NOTE: W4[5-6] must be on for 5554 Quad only.