Main components
1
Magnesium anode
2
Air vent valve (MFA)
3
Electric booster heater 8.8 kW (MFA)
4
Safety valve (MFA)
5
3-way switching valve (MFA)
6
Electrical connection
7
Cable entries
8
Maintenance flange
9
Drain stopcock
10
Buffer tank (100 l)
11
Drain stopcock
12
Heating circuit pump
13
Buffer charging pump
14
DHW tank (168 l)
15
Condenser (plate heat exchanger)
16
High limit safety cut-out (MFA)
17
Air vent valve
Figure 22: Main components in T200 indoor unit
Choosing the installation location
CAUTION
Do not install the appliance in damp
rooms!
Install the appliance in a frost free and dry room
near the draw-off point. In order to reduce line
losses, keep the distance between the indoor unit
and the outdoor unit small.
Ensure that the floor has adequate load bearing
capacity and is sufficiently level (for weight, see
section 13, Specification). The room must not be
endangered by explosive dust, gases or vapours.
If installing the appliance in a boiler room with
other heating appliances, ensure that their
operation is not affected.
Summary of Contents for Air Eagle 717
Page 2: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 2 of 76...
Page 63: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 63 of 76...
Page 64: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 64 of 76...
Page 65: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 65 of 76...
Page 66: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 66 of 76...
Page 68: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 68 of 76...
Page 69: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 69 of 76...
Page 70: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 70 of 76...
Page 71: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 71 of 76...
Page 73: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 73 of 76 16 Declaration of conformity...
Page 74: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 74 of 76...
Page 75: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 75 of 76...