BA_OCHSNER AIR EAGLE_414_717_V06_EN.docx
Page 28 of 76
Venting the system
-
To vent the system, temporarily open the air
vent valve (1) on the multifunctional
assembly.
There is another air vent valve underneath the
top appliance cladding.
-
Remove the top appliance cladding.
-
Remove the thermal insulation material
underneath.
-
To vent the system, temporarily open the air
vent valve (2).
CAUTION
Close the air vent valves after venting.
Using T200 with a heating circuit with
mixing valve
To use the T200 (MULTI TOWER) indoor unit with
a heating circuit with mixing valve, the internal
heat circuit pump must be replaced with an
adaptor.
The heating circuit pump is the left-hand pump in
the upper section of the T200.
Adaptor:
The adaptor needs to have the following
dimensions:
-
Connections 2 x 1½" MT, with flat gasket
-
Length 180 mm
-
Nominal diameter DN 25 (1")
The adaptor is available from OCHSNER as an
accessory with the item number 914383.
Subsequently, the heating circuit (or several) can
be set up externally.
Connect the components of the mixed circuit to
the following connections on the OTE controller:
-
Mixer:
PIN 15/16/N/PE
-
Mixed circuit sensor:
PIN 43/GND
-
Mixed circuit pump:
PIN 8/N/PE
Recommission the controller with heating circuit 2
in mixed configuration. In case of more than one
mixed circuit, an auxiliary module (order
no. 290197) is required.
Cooling with T200
NOTE
Only gentle cooling down to a flow
temperature of 18°C is permitted with
the T200 indoor unit!
Summary of Contents for Air Eagle 717
Page 2: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 2 of 76...
Page 63: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 63 of 76...
Page 64: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 64 of 76...
Page 65: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 65 of 76...
Page 66: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 66 of 76...
Page 68: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 68 of 76...
Page 69: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 69 of 76...
Page 70: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 70 of 76...
Page 71: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 71 of 76...
Page 73: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 73 of 76 16 Declaration of conformity...
Page 74: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 74 of 76...
Page 75: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 75 of 76...