* PROVIDES CONSTANT 
  FLOW OF 1.6 LITERS

* PROVIDES MINIMUM
  DEMAND FLOW OF

DEMAND REGULATOR

  BREATHING BAG

* 110 LITERS
* MEDICAL GRADE OXYGEN
* D.O.T. APPROVED

* REFILLABLE BY OCENCO

* 5000 P.S.I. TEST

* ALUMINUM CYLINDER

OXYGEN BOTTLE

BREATHING BAG

* VOLUME - 5 LITERS

PRESSURE GAUGE

* VISIBLE DURING USE

* READS 2000-2500 PSI WHEN CHARGED

  TO 100 PSI

PRESSURE REGULATOR
* REDUCES PRESSURE

* BOTTLE PRESSURE
  RELIEVES AT 4800

FRANGIBLE DISC
* SAFETY RELIEF

  PSI

* ACTIVATES SYSTEM
* PERMITS OXYGEN

ON-OFF VALVE

  CONSERVATION

ON

  PRESSURE OF THE

* RELIEVES EXCESS

RELIEF VALVE

  PER MINUTE

* REDUCES DEAD SPACE

* CONTROLS INHALATION

MOUTHPIECE & VALVE ASSEMBLY

  AND EXHALATION

* REMOVES CO

SCRUBBER

2

40 LITERS PER MINUTE

1) Compressed Oxygen Supply Circuit 

Medical grade oxygen is stored in a DOT approved refillable oxygen bottle that has been pressurized 
to 2250 psi and holds 110 liters of oxygen.  The oxygen flow is controlled through a series of valves 
and is activated by turning the ON/OFF valve counterclockwise.  The pressure gauge is visible at all 
times.  The oxygen moves through the ON/OFF valve into a pressure reducing regulator that reduces 
the oxygen pressure to 100 psi.  The oxygen then passes from the pressure-reducing regulator 
through a hose and into the demand regulator.  The demand regulator provides a constant flow of 1.6 
liters per minute with a minimum of 40 liters per minute upon demand.  The oxygen then moves 
through an additional hose from the demand regulator to the breathing bag. 

2) Closed Breathing Circuit 

The breathing bag is the reservoir of breathable gas and is constructed of durable urethane coated 
nylon.  Oxygen is inhaled from the breathing bag through an inhalation tube and mouthpiece.  The 
expired breath moves through the mouthpiece and to the CO2 scrubber through an exhalation tube.  
The CO2 scrubber is constructed of steel with a lithium hydroxide bed to remove CO2 from the 
expired breath.  The scrubbed breath then re-enters the breathing bag through a tube connected to 
the bottom of the scrubber and is mixed with fresh oxygen.  A relief valve is located in the center of 
the breathing bag to vent any excess pressure and to maintain the exhalation pressure of the 
breathing circuit within safe limits. 

EBA-75 FUNCTIONAL DIAGRAM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

Summary of Contents for EBA-75

Page 1: ...Page 1 of 13 INSTRUCTION MANUAL FOR THE EBA 75 CLOSED CIRCUIT ESCAPE RESPIRATOR CCER CAPACITY 3 Manual Number NH24053 Revision A ECN 3590 December 14 2015...

Page 2: ...EM DESCRIPTION OPERATION 3 OCENCO EBA 75 FUNCTIONAL DIAGRAM 4 INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE FOR USER AT REST 5 INSPECTION MAINTENANCE 6 INSPECTION CHECKLIST 7 OCENCO EBA 75 PARTS DIAGRAM...

Page 3: ...ecting the unit as explained in the Instructions for Use section on page 5 and the Inspection and Maintenance section on page 6 2 Avoid physical abuse to the unit 3 Follow all NIOSH and MSHA recommend...

Page 4: ...ves through the ON OFF valve into a pressure reducing regulator that reduces the oxygen pressure to 100 psi The oxygen then passes from the pressure reducing regulator through a hose and into the dema...

Page 5: ...r donning the goggles prescription eyeglasses can be donned by guiding the eyeglass temples through the channels provided 12 ESCAPE Proper handling maintenance and other information as supplied in thi...

Page 6: ...are provided one for each band If both seals are broken remove the unit from service 3 Inspect the apparatus for indications of abuse If the view through the case is obstructed such that a proper exam...

Page 7: ...astic loops that hold the handle straps 13 One or both of the two handle straps black nylon straps missing or broken 14 Inspect the factory service date label on the base and remove unit if past the m...

Page 8: ...13 5 PRESSUREGAUGE 4 MOUTHPIECE 3 GOGGLES 2 NOSECLIP 1 NECKHARNESS FROMLOW EREND OFSCRUBBER REGULATOR FROMDEMAND 6 11 MOUTHPIECE INHALATION 12 TO 5 7 3 4 1 ENDOFBREATHING FROMUPPER INHALATION 2 UPPER...

Page 9: ...HANDLE STRAP 18 BAND 17 LATCH SEALS 16 LATCH RELEASE RINGS 15 LATCH PIN REQUIRED HANDLE STRAP ATTACHED TO BASE OPTIONAL SHOULDER STRAP ATTACHED TO COVER 18 14 17 STORE XXXX CARRY XXXX MFG XXXX REQUIRE...

Page 10: ...from the date of manufacture if the units have been carried The end of service life for the EBA 75 is fifteen years from the date of manufacture regardless of the deployment method The Conditions of...

Page 11: ...th NIOSH Registration will enable NIOSH which approved this model of respirator to attempt to notify you if a problem is discovered that might affect the safety or performance of this respirator Regis...

Page 12: ...JMNO 1 PROTECTION SC Self contained ESC Escape CAP Capacity 2 CAUTIONS AND LIMITATIONS J Failure to properly use and maintain this product could result in injury or death M All approved respirators s...

Page 13: ...Page 13 of 13 LakeView Corporate Park 10225 82nd Avenue Pleasant Prairie Wisconsin 53158 5801 United States of America Telephone 262 947 9000 Telefacsimilie 262 947 9020 www ocenco com...

Reviews: