Page 10 of 13
SPECIFICATIONS
The EBA-75 has been designed to provide respiratory protection during escape from oxygen deficient
or hazardous atmospheres. This device enables the user to breathe independently of the ambient
atmosphere for a minimum period of 60 minutes.
Performance Data
Capacity
110 liters of oxygen
Note: proper use of the device for "User at Rest" - 6.5 hours maximum
Dimensions
21.8 x 30.2 x 11.7 cm (8.6 x 11.9 x 4.6 in)
Weight
8 lbs. (carry in operation)
Operating Environment
Minimum operating temperature 32
˚F (0˚C)
Nominal cylinder pressure
– 2000 to 2500 psi.
Service life
The EBA-75 is designed for a service life of fifteen years if properly inspected and if the conditions of
use are observed.
A Mandatory Factory Service action shall occur ten years from the date of manufacture if the units
have been stored and five years from the date of manufacture if the units have been carried. The end
of service life for the EBA-75 is fifteen years from the date of manufacture regardless of the
deployment method.
The Conditions of Use for the EBA-75 are:
A. Daily and 90-Day Inspections as defined in this manual.
B. Caring for the EBA-75 as defined in this manual.
C. Acceptable Storage of the EBA-75: the EBA-75 must be stored in an Ocenco approved
carry case and securely fastened to a wall or other substantial structure. Devices stored on
vehicles must be secured against movement in a fully enclosed metal container.
D. Acceptable Carry of the EBA-75: the EBA-75 must be carried in an Ocenco approved carry
case.
Scrubber life is limited to one escape event or one oxygen charge.
NOTE:
If escape is necessary don the device regardless of temperature.
DISPOSAL
Safe disposal is necessary after the EBA-75 has been used, fails inspection, or has exceeded the
fifteen year service life. Ocenco EBA-75s must be disposed of in accordance with hazardous material
disposal regulations.