background image

BreathCare PAP

Positive Airway Pressure Device

User’s Manual

Please read the user's manual closely before using! 
Please check the certificate or the package for the production date.

1030400-0A

BreathCare

APAP

Suzhou Yuyue Medical Technology Co.Ltd
No.9 Jinfeng Road,Suzhou Science & T echnology
Town, Suzhou,Jiangsu,215163,PRC 
http://www.yuwell.com

The manufacturer reserves the right to change the contents
Please read the user's manual closely before using! 

Paper

Summary of Contents for BreathCare YH-360CPAP

Page 1: ...certificate or the package for the production date 1030400 0A BreathCare APAP Suzhou Yuyue Medical Technology Co Ltd No 9 Jinfeng Road Suzhou Science Technology Town Suzhou Jiangsu 215163 PRC http ww...

Page 2: ...sk barotrauma severe lung pneumothorax dehydration cerebrospinal fluid leakage recent intracranial surgery intracranial trauma and etc Dry mouth nosebleeds bloating ear or sinus discomfort eye irritat...

Page 3: ...wise to decrease START Start Stop button Knob Note Fill the humidifier with water which should not exceed the maximum level MAX otherwise the water may enter into the air hose and the device Please fi...

Page 4: ...s per hour Used time the time duration for the last therapy h Average pressure the average pressure for the last therapy cmH20 hPa Average leak volume average air leak volume per minute for the last t...

Page 5: ...n off Level 1 for the lowest level and Level 6 for the highest level Levels 1 6 are equivalent to the following temperatures with the accuracy of 4 respectively Note These temperatures are measured wi...

Page 6: ...knob to return to the standby interface Fig 6 2 In the APAP mode set the maximum pressure minimum pressure therapy pressure and initial pressure by the same operational order Remark No therapy pressu...

Page 7: ...return option and press the knob to return to the standby interface Fig 6 2 5 Select the Ramp min 6 Select the Humidity Note Press the START button and the knob at the same to enter into the clinical...

Page 8: ...ce with a dry and clean cloth Note Ensure that the size of the air filter cotton is proper so as to prevent water or dust from going into the PAP device B Air hose inspection Inspect the air hose for...

Page 9: ...n the figure The removable cover the partition and the humidifier tank body should be properly installed with their embossing positions aligned 14 15 XII Therapy parameter storage The PAP device shoul...

Page 10: ...he nose mask type is unqualified The humidify level is low The nose has other disorders The humidify level is too high The temperature difference between inside and outside of the hose is high Decreas...

Page 11: ...duce the service life of the product When the heated humidifier is used please place the device in a height below the user s head to prevent any water from backflowing into the air hose and the nose m...

Page 12: ...eated humidifier Plastic hose 1 8m approx PC injection molding stainless steel bottom TPE seal strip 4 20cm H2O hPa adjustable increment 0 5cm H2O hPa 4 20cm H2O hPa adjustable increment 0 5cm H2O hPa...

Page 13: ...s declaration electromagnetic immunity Immunity test Electrostatic discharge ESD GB T17626 2 6 kV contact 8 kV air 6 kV contact 8 kV air 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycle...

Page 14: ...MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people...

Page 15: ...I Warranty Generally Suzhou Yuyue Medical Technology Co Ltd provides the warranty periods for the product and its accessories as follows The warranty for this product applies only for the first time b...

Page 16: ...ase Date Dealer User Date The following cases are not included in the warranty scope 1 Failure or damage caused by any unauthorized modification and repair by non authorized technicians from yuwell co...

Page 17: ...nt electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the BreathCare PAP device as recommended below according to t...