Document UT-MT-0779_EN
Page 32 of 37
Edition 23/04/2019
Supersedes edition 06/03/2019
LED INSET RUNWAY EDGE LIGHT LIRE
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
4.8
GASKETS
4.8.1
Gasket examination
Every time a fixture is opened each O-Ring must be examined as described below and
replaced if necessary.
Any O-Ring that is stretched, torn, has a permanent set or some other defect, which
would prevent it from obtaining a water-tight seal must be replaced with a new O-
Ring.
Remove the fixture from the base and open it following instructions of “Removing
and Opening the Light Unit From the Base”.
Light assembly is equipped with the following gaskets:
two O-Ring between dome and lower cover (Figure 23 - n°2 and 3);
O-Ring around the dome (Figure 23 - n°3);
O-Ring between fixture and 12” shallow base (Figure 23 - n°7);
prism gasket mounted between prism and dome (Figure 24- n°2).
1.
Dome
2.
O-Ring between dome
and lower cover
3.
O-Ring between dome
and lower cover
4.
O-Ring around the
dome
5.
Lower Cover
6.
12" Shallow base
7.
O-Ring between
fixture and 12"
Shallow base
Figure 23– Fixture Gaskets
Figure 24 – Prism Gasket