Document UT-MT-0779_EN
Page 20 of 37
Edition 23/04/2019
Supersedes edition 06/03/2019
LED INSET RUNWAY EDGE LIGHT LIRE
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
STEP A
B
ACTIVITY DESCRIPTION
8
Push the base into the recess until its upper side is at the level of the
pavement surface; take care no sealer flowing inside the base. Align the notch
of the base with the markings on the pavement surface.
9
/
Observing the circular level fixed on the jig, level the jig by operating the three
leveling lobe knobs (Figure 13). If necessary, a weight may be placed on the jig
to hold the light base in position.
The remainder of the space between the sides of the shallow base and the
drilled hole should be filled with sealer up to approx 25 mm from the
pavement, according to the local needs.
Fill the remaining 25 mm with a suitable joint sealing filler.
10
/
Observing the circular level fixed on the jig, level the jig by operating the three
leveling lobe knobs (Figure 13). If necessary, a weight may be placed on the jig
to hold the light base in position.
When the shallow base is in its final position, the conduit(s) must be properly
jointed to the hole(s) provided on the shallow base. This(these) hole(s) can be
provided either on the wall either on the bottom, the number and the
dimensions according to customer requirements (Figure 12).
The remainder of the space between the sides of the shallow base and the
drilled hole should be filled with sealer up to approx 25 mm from the
pavement, according to the local needs.
Fill the remaining 25 mm with a suitable joint sealing filler.
11
/
Lay the secondary power cable, equipped with a suitable two-pole receptacle
kit, and the grounding wire inside the cable duct.
12
To install the fixture place the O-Ring around the dome (Figure 11- n°1) and
between fixture and base (Figure 11- n°3).
Connect the plug and the grounding wire of the fixture with the receptacle and
the grounding wire of the base; press the fixture by hand onto the base and
secure it using the six locking screws complete with washer, one drop of screw
paste (e.g. Dow Corning Molycote 1000) should be applied to the screws
before installation.
Tightening torque is 35 Nm.
ATTENTION: The fixture is subject to mechanical damage and/or optical
misalignment if not properly seated on the base flange.