33
TO SET - DIVE TIME REMAINING ALARM
(while in the Surface Mode)
Factory set for 0:00 (minutes), the Dive Time Remaining Alarm
can be set to values between 0:00 and 0:20 (minutes) in
increments of 1 minute.
• Press Both buttons simultaneously, release when SET: 2
appears.
• Press and release the Advance (Front) button, the Units
screen appears with the set point flashing.
• Press the Advance (Front) button
9 more times.
• The graphic
dtr
, and Alarm (speaker) and Dive Mode
icons appear with the
Dive Time Remaining
value
flashing (Fig. 33).
• Press and release the Select (Side) button to advance the
Alarm value in increments of one minute, or press and hold
the button to scroll through the Set Points.
• Press the Advance (Front) button to accept the setting and
advance to Set Max PO2 Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 33 - Set Dive Time Remain-
ing Alarm