PRODUCT SP5 SERVICE GUIDE
SUPPORT: TOLL‐FREE: 800‐435‐3483 | FAX: 510‐569‐5404 | EMAIL: [email protected]
7
B. Secure the
BODY (29)
in a padded vise with the yoke facing upwards. Apply a modified 1” crow’s foot wrench or modified
1” yoke nut socket over the
DVT YOKE RETAINER (30)
. Using a firm steady force, remove
DVT YOKE RETAINER (30)
by turning
it counter‐clockwise.
DO NOT
use impact or heat to remove
(Fig. 6)
.
Fig. 6
CAUTION:
It
is
important
that
the
wrench
or
socket
is
properly
seated
over
the
DVT
Yoke
Retainer
(30)
to
prevent
marring
or
damaging
the
part.
CAUTION: Tighten the vise only as needed to hold the first stage secure; DO NOT over tighten.
Doing so will result in deformation of the parts, rendering them unusable.
C. Remove the
DVT YOKE RETAINER (30)
,
YOKE (2)
,
STYLING CUP (3a)
,
and
PROTECTOR CAP (17)
. Inspect the sealing edge
(which mates to the valve face) of the
DVT YOKE RETAINER (30)
for scratches or deformation; replace if any found.
D.
Remove
and
discard
both
DVT RETAINER O‐RINGS (34, 35)
(schedule A) and
DO NOT REUSE
.
E.
Remove
the
FILTER (33)
,
PLUNGER SPRING (32)
and
PLUNGER (31)
from the
DVT YOKE RETAINER (30)
. Discard the
FILTER
(33)
and
PLUNGER (31)
(schedule A) and
DO NOT REUSE
(Fig. 7)
.
Fig. 7