background image

22

PROPLUS 4.0 OPERATING MANUAL

© Pelagic, 2019

Doc. No. 12-5669-r01 (1/18/19)

5: DTR (DIVE TIME REMAINING)

The Dive Time Remaining Alarm allows you to set an alarm to go off with a designated reserve. Settings include OFF or  5 - 20 min of dive 

time remaining.

SEL

ADV

toggle 

setting

save setting, 

(proceed to Set Turn Alarm if 

ON or OFF, to Set DTR Alarm 

if SET)

Choose OFF, ON, or SET

flashing OFF, ON, 

or SET

SEL

ADV

toggle 

setting

save 

setting

Set DTR Alarm

DTR Alarm Triggered

flashing

flashing 

15 - 20 min

6: TURN PRESS

The Turn Pressure Alarm allows you to set an alarm to go off at a designated turn pressure. You may choose from OFF or 1000 to 3000 

PSI (70 to 205 BAR) in increments of 250 PSI (5 BAR).

SEL

ADV

toggle 

setting

save setting, 

(proceed to Set End Alarm if 

ON or OFF, to Set Turn Alarm 

if SET)

Choose OFF, ON, or SET

flashing OFF, ON, 

or SET

SEL

ADV

toggle 

setting

save 

setting

Set Turn Alarm

Turn Alarm Triggered

flashing

flashing 

7: END PRESS

 The End Pressure Alarm allows you to set an alarm for when you reach a designated end pressure. You may choose from 500 to 1500 PSI 

(20 to 105 BAR) in increments of 100 PSI (5 BAR).

  NOTE: The Low Pressure Alarm only considers gas 1. 

SEL

ADV

toggle 

setting

save setting, 

(return to Set Alarms Lead-in if 

ON or OFF, to Set Turn Alarm 

if SET)

Choose OFF, ON, or SET

flashing OFF, ON, 

or SET

SEL

ADV

toggle 

setting

save 

setting

Set End Alarm

End Press Alarm Triggered

flashing

flashing 

Summary of Contents for Proplus 4.0

Page 1: ...1 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 PROPLUS 4 0 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...S 23 1 WATER TYPE 23 2 UNITS 23 3 DEEP STOP 24 4 SAFETY STOP 24 5 ALGORITHM 24 6 CONSERVATIVE FACTOR 25 7 GLO BACKLIGHT DURATION 25 8 SAMPLE RATE 25 9 BLUETOOTH 26 SET TIME 26 SET MODE 27 HISTORY 27 S...

Page 3: ...Loading Bar Graph TLBG Pre Dive Planning Sequence PDPS OceanLog and Dual Algorithm are all registered and unregistered trademarks trade names and service marks of Pelagic All rights are reserved PATE...

Page 4: ...4 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 Welcome to OCEANIC and THANK YOU for choosing the ProPlus 4 0...

Page 5: ...5 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GETTING STARTED...

Page 6: ...t is your preference Disabling the H2O ACT feature is described in the Dive Surface Mode chapter p 26 Upon activation the unit will enter a Diagnostic Mode The ProPlus 4 0 checks the display and volta...

Page 7: ...n 7 Tissue Loading Bar Graph 8 Log 9 History 10 Surface Time 11 Time To Fly 12 Oxygen Saturation 13 Variable Ascent Rate Indicator 14 Algorithm 15 Gas 16 Value is Maximum 17 Safety Stop 18 Descend Asc...

Page 8: ...ey are also used to enter settings activate the backlight and acknowl edge the audible alarm Throughout this manual they will be referred to as the ADV and SEL buttons Pressing different combinations...

Page 9: ...ens to advance or step through menus to toggle or change setpoints SEL ADV to scroll quickly changing setpoints to scroll quickly through menu lead in screens selections SEL ADV to select access step...

Page 10: ...10 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 DIVE FEATURES...

Page 11: ...rol shifts to slower compartments This is a feature of the decompression model that is the basis for multilevel diving one of the most important advantages that Oceanic dive computers offer O2 MIN OXY...

Page 12: ...elagic Z algorithm performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative than the DSAT version especially at shallower depths To create even greater margins...

Page 13: ...r Decompression during the dive complete the Decompression obligation then descend below 30 ft 9 m the Safety Stop Main will appear again upon ascent to within 5 ft 1 5 m deeper than the Safety Stop d...

Page 14: ...following situations shall activate the Alarm 1 beep per sec for 10 sec Conditional Violation Delayed Violations 1 2 3 Ascent Rate too fast full bar graph PO2 increases to 20 Alarm Set Point and at t...

Page 15: ...15 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM SURFACE MODE...

Page 16: ...ions Some screens simply display data whereas the other screens are lead ins to sub menus and settings Press the SEL button to choose menus or options from the Main Menu when available All Main Menu s...

Page 17: ...from 23 50 to 0 00 hr min 10 minutes after surfacing from a dive The SAT Desat counter shall provide calculated time for Tissue Desatuation at sea level taking into consideration the CF Conservative F...

Page 18: ...ive is activated in either Norm or Gauge mode After the post dive 24 hour period has elapsed and the unit shuts off the first dive of the next activation period will be recorded as dive 1 In the event...

Page 19: ...ption will not be displayed in the Set Gas menu until 24 hours elapse after the last dive If subsequent Air dives are made during this period an FO2 value of 21 should be chosen NOTE When FO2 is set f...

Page 20: ...OFF or ON SET ALARMS Within this submenu you can customize the following seven alarm settings Within this menu you can customize the following seven alarm settings SEL ADV next item in Main Menu acces...

Page 21: ...redetermined amount of dive time SEL ADV toggle setting save setting proceed to Set TLBG Alarm if ON or OFF to Set EDT Alarm if SET Choose OFF ON or SET flashing OFF ON or SET SEL ADV toggle setting s...

Page 22: ...may choose from OFF or 1000 to 3000 PSI 70 to 205 BAR in increments of 250 PSI 5 BAR SEL ADV toggle setting save setting proceed to Set End Alarm if ON or OFF to Set Turn Alarm if SET Choose OFF ON or...

Page 23: ...next item in Main Menu access Set Utilities Menu 1 WATER TYPE The Water Type feature allows you to set SALT or FRESH water environment for accurate depth calculations SEL ADV toggle setting save sett...

Page 24: ...available 3 or 5 min Safety Stop at depths of 10 15 or 20 ft or 3 4 5 or 6 m SEL ADV toggle setting Set Safety Stop SEL ADV toggle setting Set Stop Time or 5 00 min sec save setting SEL ADV toggle set...

Page 25: ...ory becomes full The ProPlus 4 0 Log and Download data is stored separately in different partitions of the memory The Log only stores a short sum mary of each dive Alternately the Download function st...

Page 26: ...d off or a dive is started The ProPlus 4 0 returns to sniffing mode when the ProPlus 4 0 returns to Surface Mode after a dive or a but ton is pushed to wake the computer from Sleep Mode on the surface...

Page 27: ...ed water temperature deepest recorded dive longest recorded dive SN SERIAL NUMBER Information displayed on the Serial Number screen should be recorded and kept with your sales receipt it will be requi...

Page 28: ...28 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM DIVE MODE...

Page 29: ...yed may change This is to indicate a safety recommendation warning or alarm The following information in this chapter demonstrates and describes an uneventful dive in terms of safety Alarms are descri...

Page 30: ...00 min sec as long as you stay within 3 m 10 ft above or below the stop While Deep Stop Main is displayed you may access Alt displays by pressing the ADV button to cycle through them They are similar...

Page 31: ...ernationally recognized training agency Overview All dives begin with gas 1 The GAS defaults to 1 after 10 minutes on the surface Gases cannot be switched while in surface mode The Gas Switch Menu can...

Page 32: ...ECOMPRESSION STOP MAIN Decompression deco Stop Main will display upon ascending to within 10 ft 3 m below the Deco Stop depth The Full Stop icon both Arrows with Stop Bar will be displayed solid While...

Page 33: ...lashing DELAYED VIOLATION 2 If the calculated Decompression obligation requires a Stop Depth between 60 ft 18 m and 70 ft 21 m operation will enter Delayed Violation 2 The audible alarm will sound Add...

Page 34: ...VIO violation is to flash for 10 minutes then it will alternate with NOR Norm or GAU Gauge until 24 hours elapse with no dives During that 24 hours VGM lockout does not allow access to the Set Gas Pla...

Page 35: ...saturation reaches the Warning Level the audible alarm sounds and the O2 oxygen saturation value will flash in place of Depth Depth will be restored when the audible alarm is silenced flashing ALARM I...

Page 36: ...ue will flash in place of Deco Stop Time Upon silencing Current Depth is to be restored the graphics UP and O2 are to alternate and the Up Arrow is to flash until on the surface ALARM ON SURFACE If O2...

Page 37: ...37 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GAUGE MODE...

Page 38: ...Main Menu when available MAIN MENU ALT 1 Last Dive Max Depth Dive Time ALT 2 Elevation Time Temperature FLY LOG SET ALARMS SET UTIL SET TIME SEL MODE HISTORY SERIAL NUMBER Return to Home Menu SEL ADV...

Page 39: ...39 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 REFERENCE...

Page 40: ...tight integrity are not covered under the terms of the 2 year limited warranty To Obtain Service Take your ProPlus 4 0 to an Authorized Oceanic Dealer or send it to the nearest Oceanic Regional Facil...

Page 41: ...th fresh water and allow to dry overnight or blow dry with a hair dryer set at no heat Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing Inspect the Bu...

Page 42: ...Two readings are taken the second reading 5 seconds after the first The readings must be within 1 foot 30 cm of each other to record that ambient pressure as the current Altitude No adjustments are ma...

Page 43: ...43 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 TECHNICAL DATA...

Page 44: ...0 05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0...

Page 45: ...0 03 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526...

Page 46: ...Gauge displays Dives 1 to 24 Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores max 24 entries per day 99 entries in memory for viewing After 24 dives in one day or 99 dive...

Page 47: ...after the dive Surface Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Points Air 21 to 100 1 PO2 Value 0 00 to 5 00 ATA 01 ATA O2 Saturation...

Page 48: ...time FPM Feet Per Minute FT Feet depth GTR Gas Time Remaining HR Hour M Meters depth MAX Maximum M D D M Month Day Day Month MIN min Minutes time MPM Meters Per Minute NDC No Deco DTR NDL No Deco Limi...

Page 49: ...ase ___________________________________________________________________________________________________ Purchased from _________________________________________________________________________________...

Page 50: ...50 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 ProPlus 4 0 DIVE COMPUTER OPERATING MANUAL...

Reviews: