19
PROPLUS 4.0 OPERATING MANUAL
© Pelagic, 2019
Doc. No. 12-5669-r01 (1/18/19)
SEL
ADV
to
Data 3
Log Data 2
TLBG* with the max
accumulation segment
flashing, others fixed up to
end of dive accumulation.
All segments flashing if a
Delayed Violation. No TLBG
if Gauge Mode.
elapsed dive time
max depth
max ascent
rate
*TLBG = Tissue Loading
Bar Graph
SEL
ADV
to
Main Menu
Log Data 3
gas mix
FO2 (% O2)
% O2 Satura
-
tion
at end of dive,
- - if the dive
entered
Violation
Gauge Mode
gas #
NOTE: Log Data 3 only displays for nitrox
dives; it is bypassed if the dive was an air dive.
highest
PO2
reached
during
the dive
SET GAS
Pressing the SEL button while viewing the Set Gas Lead-in screen accesses the Set FO
2
screen. Within this screen you can change the gas mix from
Air to any nitrox mix between 21 - 100 FO
2
(% O
2
). Nitrox mixes are displayed with their corresponding MOD (Maximum Operating Depth) and the
current PO
2
Alarm setting. If you do not like the current PO
2
Alarm setting, it can be changed in the screen that follows after saving a nitrox gas mix
setting.
NOTE: Once a nitrox dive is made, the Air option will not be displayed in the Set Gas menu until 24 hours elapse after the last
dive. If subsequent Air dives are made during this period, an FO2 value of 21 should be chosen.
NOTE: When FO2 is set for AIR, oxygen related data (such as PO2, % O2) will not be displayed at any time during the dive, on
the surface, or in Plan Mode. Though these oxygen values will be tracked internally for use in any subsequent nitrox dives.
NOTE: Gas 1 cannot be set to OFF.
FO2 Default
The FO2 Default setting follows Set FO2 and PO2 for gases 1-3. When the FO2 50% Default is set On and FO2 is set for a numerical value, 10 min
-
utes on the surface after that dive the FO2 will be displayed as 50 and further dives will be calculated based on 50% O2 for oxygen calculations
and 21% O2 for Nitrogen calculations (79% Nitrogen), unless FO2 is set before the dive.
FO2 will continue to reset to the FO2 50% Default after subsequent repetitive dives until 24 hours elapse after the last dive, or the
FO2 50% Default is set Off.
SEL
ADV
Set Gas Lead-in
to Set
Gas 1 FO
2
SEL
ADV
adjust FO2
setting
save
setting
MOD
current
PO2 Alarm
setting
Set Gas 1 FO
2
FO2 (O2%)
setting
SEL
ADV
adjust PO2
setting
save
setting
PO2 Alarm
setting
Set Gas 1 PO
2
FO2 (O2%)
setting
NOTE: Set Gas 2/3 FO
2
and PO
2
are similar to Set Gas 1.
Summary of Contents for Proplus 4.0
Page 5: ...5 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GETTING STARTED...
Page 10: ...10 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 DIVE FEATURES...
Page 15: ...15 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM SURFACE MODE...
Page 28: ...28 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 NORM DIVE MODE...
Page 37: ...37 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 GAUGE MODE...
Page 39: ...39 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 REFERENCE...
Page 43: ...43 PROPLUS 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5669 r01 1 18 19 TECHNICAL DATA...