8.  Testing and operation

This pump can be set up to work automatically - a thermostat is installed on the steam pipe which 

only allows the pump to operate when the steam generator is producing steam. The amount of 

aroma introduced into the steam line is controlled by the RUN and INTERVAL settings. 

The pump can also be controlled via a button (fragrance on demand) this button is water proof 

and can be installed inside the steam room. When the button is pushed the pump will be turned 

on or off. This gives the option for users to choose between having aroma or not, which is useful in 

commercial installations where users may like or dislike aroma. 

The amount of aroma introduced into the steam line is controlled by the RUN and INTERVAL 

settings.

i.  Fill the fragrance container with a diluted solution of fragrance.

ii.  Turn on the power supply

iii.  Press the “on/off” key (Power LED illuminated) - the default settings is run time 5 seconds with a 1 

minute interval.

iv.  Turn on the steam generator, when the temperature of the steam line reaches 85oC the 

temperature indicator LED will be illuminated and the pump will operate. 

v.  Note that for the first operation it may require one or two operations of the pump before the 

fragrance enters the steam line depending upon the distance to T piece. (note the pump is self 

priming and does not require bleeding in.

vi.  Depending on the size of the steam room and the concentration of fragrance required you 

can set the run and interval periods to suit. Press the run button to choose the pump working 

time; 5 seconds, 10 seconds or 15 seconds, the relevant indicator LED will be illuminate. Press 

the interval button to choose the interval time say 1 minutes, 2 minutes and three minutes (the 

relevant indicator LED will be illuminated)

Using Steam aroma concentrates the typical dilution rate is 1 part concentrate to 20 parts of water 

but you may also vary this to suit user requirements – increase concentration for a more intense 

aroma.

9.  Warranty

The product is guaranteed for 12 months from the date of purchase; for after sales service please 

contact Oceanic Saunas Ltd - 01902 450 550 www.oceanic-saunas.co.uk

Summary of Contents for OC-FP-1 Way

Page 1: ...CT IMAGE Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam 1 Way Fragrance Pump Assembly and operating manual OC FP...

Page 2: ...co uk 2 Fragrance Pump Manual Table of contents 1 Introduction 3 2 Safety Precautions 3 3 Parts List 3 4 Parameter and functions 3 5 Electrical Diagram 3 6 OC EP 1 way Function instructions 4 7 Instal...

Page 3: ...ial installations ensure signage is used to display what type of aroma is used in the case of users with allergies 3 Parts List 240v 12v adapter 4mm inlet silicon hose 2m 4mm outlet silicon hose 3m Te...

Page 4: ...ED When on pump will run every minute 10 2 minute interval time indicator LED When on pump will run every 2 minutes 11 3 minute interval time indicator LED When on pump will run every 3 minutes 12 5 s...

Page 5: ...ce pump onto a wall using screws and plugs iii Use the 2m silicon hose Supplied to connect the fragrance container to the fragrance inlet port iv Use the 3m silicon hose provided connect from the Esse...

Page 6: ...seconds with a 1 minute interval iv Turn on the steam generator when the temperature of the steam line reaches 85oC the temperature indicator LED will be illuminated and the pump will operate v Note t...

Page 7: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 7 Fragrance Pump Manual...

Page 8: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 8 Fragrance Pump Manual...

Reviews: