Sauna & Steam
Oceanic Saunas 01902 450 550 [email protected]
5
Fragrance Pump Manual
7. Installation and Operation
Figure 3
Temperature sensor
Non return valve
Silicon Hose 3m max
Silicon Hose 2m maximum
Fragrance
12V Transformer
Fragrance On Demand
Button
15mm Tee Junction
Steam Line
i. Install the pump in close proximity to the steam generator with a suitable mains power
supply for the mains adapter. Note that the fragrances container can be positioned at a
maximum of 2 meters below the pump.
ii. Fix the fragrance pump onto a wall using screws and plugs.
iii. Use the 2m silicon hose (Supplied) to connect the fragrance container to the fragrance inlet
port.
iv. Use the 3m silicon hose provided connect from the Essence outlet to the steam line by
inserting the 15mm Tee as the figure 3
v. Attach the temperature sensor to steam pipe using a cable tie or cotton wool and tape then
connect the pin into the socket on the fragrance pump.
vi. Connect the adapter to the power sockets. Connect the adapter to power supply.
vii. If you have chosen the FOD (fragrance on demand) button. Connect the FOB button to FOD
socket on the fragrance dispenser and mount the button inside or outside the steam room
so the user can decide when they want fragrance.