The OWC2412QC unit is equipped with a standard 10-foot service cord which has a
6-20P plug configuration. The molded LCDI (Leakage Current Detection & Interrup-
tion) device serves as a means of electrical protection.
UNIT/MODEL
PLUG CONFIGURATION
RECEPTACLE
208-230 VOLT
OWC2412QC
NEMA 6-20R
20A-240 VOLT
NEMA 6-20P
SPOT COOLER
The OWC2412QC can be used in an open environment to cool specific objects or
"spots". Spot Cooling is a convenient and economical way to provide air conditioning
where cooling the entire space is not viable. Cool air is discharged from the units
grille and is directed where it is needed. A nozzle kit can be used to improve the
velocity.
ROOM AIR CONDITIONER
One feature of the OWC2412QC is it operates as a room air conditioner because water
is used as the means for heat rejection. The major advantage of water-cooled air
conditioning is the convenience of connecting water hoses, or lines, as compared to
the installation of condenser air ducts used for air-cooled portables. A variety of hose
kit lengths are available that can be used for connecting to a water supply and drain,
while providing portability within the conditioned space.
APPLICATIONS
ELECTRICAL CONFIGURATION
CAUTION: DO NOT USE THE LCDI AS AN ON/OFF SWITCH FOR THE UNIT
Thermostat
Evaporator Fan
Discharge “Cool”
Grille and
Washable Filter
Return Air
Inlet
Hose Kit Cubby