17
O
TS PO
WER
CO
M
O-RING REPLACEMENT
It is recommended that the o-rings be are serviced per
Manufacturer Recommended Maintenance Schedule. Anytime
the Rubber Armored Base or Transducer is removed, the o-rings
should be cleaned, inspected and lubricated. Use only o-rings
supplied by OTS for this purpose. Use of aftermarket or otherwise
sourced o-rings will void any warranties. Clean, inspect and
lubricate all o-rings even if new.
1. Remove the damaged O-Ring using a dull plastic tool. Ensure
that no damage is done to the sealing surfaces of the unit.
2. Lightly grease O-Ring with grease included in the O-Ring
replacement kit.
3. Place the O-Ring gently into the O-Ring grooves, taking extra
care not to stretch the rubber of the O-Ring. Ensure the O-ring
rests compeletly inside the groove.
4. To replace the Sealing Screw O-rings, there is a second set of
threads in the Rubber Armored Base, continue to unscrew by
pulling lightly on the Sealing Screw while unscrewing counter-
clockwise. The Sealing Screw will extract exposing the
Sealing Screw O-rings.
TRANSDUCER REMOVAL
AND REPLACEMENT
To remove, service and replace
the Transducer, follow these
instructions:
1. Locate the Transducer Ring
underneath the transducer.
2. Turn the Transducer Ring
clockwise to remove
the transducer. DO
NOT TO TWIST THE
TRANSDUCER. Twisting
the Transducer will damage the unit.
3. Pull the Transducer free by lifting straight up and replace
with the undamaged module. Turn the Transducer Ring
counterclockwise to secure the transducer to the unit.
4. The Transducer also needs to be removed for use with the
CDK-6 Surface Conversion Kit (900015-007).