should be cleaned, inspected and lubricated.
Use only o-rings supplied by OTS for this purpose. Use
of aftermarket or otherwise sourced o-rings will void any
warranties. Clean, inspect and lubricate all o-rings even if new.
1. Remove the damaged O-Ring using a dull plastic tool.
Ensure that no damage is done to the sealing surface of the
unit.
2. Lightly grease O-Ring with grease included in the O-Ring
replacement kit.
3. Place the O-Ring gently into the O-Ring grooves, taking
extra care not to stretch the rubber of the O-Ring. Ensure
the O-ring rests compeletly inside the groove.
4.
To replace the Sealing Screw O-rings, there is a second set
of threads in the Rubber Armored Base, continue to unscrew
by pulling lightly on the Sealing Screw while unscrewing
counter-clockwise. The Sealing Screw will extract exposing
the Sealing Screw O-rings.
TRANSDUCER REMOVAL AND REPLACEMENT
To remove, service and replace the Transducer, follow these
instructions:
1.
Locate the Transducer
Ring underneath the
transducer.
2. Turn the Transducer Ring
clockwise to remove
the transducer. DO
NOT TO TWIST THE
TRANSDUCER. Twisting
the Transducer will
damage the unit.
3.
Pull the Transducer
free by lifting straight up and replace with the undamaged
module. Turn the Transducer Ring locking collar
counterclockwise to secure the transducer to the unit.
4.
The Transducer also needs to be removed for use with the
CDK-6 Surface Conversion Kit (900015-007).