ATA100 INSTALLATION MANUAL
14
912S-03333-01.05
21/04/2020
2.3.3 Data Ports
There are multiple data Input and Output ports available for connection via the rear
connector panel. The ports use IEC-61162-1/2 (NMEA0183) and can be confi gured for 4800,
9600 or 38400 baud.
Port
Output
Input
Sensor 1
ABK, ACA, ACS, ALC, ALF, ALR,
ARC, EPV, GBS, GGA, GSA, GSV,
HBT, LR1, LR2, LR3, LRF, RMC,
SSD, TRL, TXT, VDM, VDO, VER,
VSD
ABM, ACA, ACK, ACN, AIQ, AIR, BBM,
DTM, EPV, GBS, GGA, GNS, GSA, GSV,
HBT, HDG, HDT, LRF, LRI, RMC, ROT,
SSA, SSD, SPW, THS, VBW, VSD, VTG
Sensor 2
Sensor 3*
DGPS
ECDIS
LR
Talkers:
GP,GN,GA
Incoming DGNSS sentences
LC,IN
Incoming EPFS sentences
AI
Outgoing AIS Sentences
GP
Outgoing Internal GPS Sentences
All other sentences may be presented from any talker.
All of the ports may be used concurrently, however in the case that the same TALKER/
SIGNATURE combination is received though two or more ports, the port that fi rst received
the sentence takes precedence until such time as the sentence has not been received on
that port for 5 seconds at which point precedence will revert to the next port the sentence
is received on.
* Sensor 3 can also be used for RTCM SC104 V2.3 data from a differential GNSS receiver.
NOTE: All Inputs and Outputs can be confi gured in the Settings - System - Input/
Output section covered on page 30 of this manual.
2.3.4 Relay Connections
To enable the operation of an external system or device the ATA100 is equipped with relay
contacts that activate when an alarm is activated. There is a common connection with one
normally open contact and one normally closed contact.
The contacts operate simultaneously and are rated at 2 Amps continuous.
Max. switching voltage:125VAC, 60VDC
Max. switching current: 1A
Summary of Contents for ATA100
Page 1: ...Installation Manual English Class A AIS Transceiver www oceansignal com ATA100 ...
Page 7: ...21 04 2020 912S 03333 01 05 7 ATA100 INSTALLATION MANUAL 1 5 Example Systems ...
Page 12: ...ATA100 INSTALLATION MANUAL 12 912S 03333 01 05 21 04 2020 ...
Page 24: ...TEMPLATES 22 ...
Page 25: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING ...
Page 26: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING 24 ...
Page 27: ......
Page 28: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING ...
Page 29: ...TEMPLATES 27 ...