1: Introduction 

 

 

MFPF100-2: Two-Channel MultiFrequency Phase Fluorometer. The two-channel unit 
includes two thermistors. 

The thermistor option is used for temperature logging, calibration and temperature correction. 

Shipment Components 

The following equipment and information ships with the MFPF: 

‰

 

Single-Channel MFPF (MFPF100-1) 

Includes one thermistor. 

 

Or,  

‰

 

Two-Channel MFPF (MFPF100-2)

 

Includes two thermistors. 

‰

 

AC power supply

 

 

(Input AC100-240V, 50-60 HZ, 0.3A) (Output DC 6V 2A) (Model #EPAS-101W-06) 

‰

 

USB Cable 

‰

 

Software and Technical Resources CD

 

Each order ships with the Ocean Optics 

Software and Resources CD

. This disc contains software, 

operating instructions, and product information for all Ocean Optics software, spectrometers, and 
MFPF spectroscopic accessories. You need Adobe Acrobat Reader version 6.0 or higher to view 
these files. Ocean Optics includes the Adobe Acrobat Reader on the 

Software and Technical 

Resources CD

Ocean Optics software requires a password during the installation process. You can locate 
passwords for the other software applications on the back of the 

Software and Technical 

Resources CD

 package. 

‰

 

Packing List 

The packing list is inside a plastic bag attached to the outside of the shipment box (the invoice 
arrives separately). It lists all items in the order, the shipping and billing addresses, and any items 
on back order. 

Additional Recommended Equipment 

‰

 

FOXY, HIOXY or FOSPOR Oxygen Sensor Probe

 

‰

 

FOXY-CAL, HIOXY-CAL, FOSPOR-CAL

 

This is an optional factory calibration service for environments from 0 to 80ºC. 

‰

 

MFPF Software

 

The MFPF software runs in the background to gather data from the MFPF unit for the main 
interface, OOISensors software. 

MFPF-00000-000-02-0606                                      

Summary of Contents for MFPF100-1

Page 1: ...47 Fax 727 733 3962 8 a m 8 p m Mon Thu 8 a m 6 p m Fri EST Ocean Optics B V Europe Ocean Optics B V Europe Geograaf 24 6921 EW DUIVEN The Netherlands Phone 31 0 26 3190500 Fax 31 0 26 3190505 E mail...

Page 2: ...the prior consent of Ocean Optics Inc in any form of binding or cover other than that in which it is published Trademarks All products and services herein are the trademarks service marks registered t...

Page 3: ...D output with the naked eye once the red cap is removed To verify there is power to the instrument place a white piece of paper in front of LED 1 2 Do not open the instrument case High voltage is pres...

Page 4: ...Important Safety Notices ii MFPF 00000 000 02 0606...

Page 5: ...pter 1 Introduction 1 MFPF System Overview 1 Applications 2 Models 2 Shipment Components 3 Additional Recommended Equipment 3 Chapter 2 Installation 5 Overview 5 Software Installation 5 Hardware Insta...

Page 6: ...Table of Contents ii MFPF 00000 000 02 0606...

Page 7: ...nsors software for use with the MFPF unit Product Related Documentation You can access documentation for Ocean Optics products by visiting our website at http www oceanoptics com Select Technical Oper...

Page 8: ...About This Manual iv MFPF 00000 000 02 0606...

Page 9: ...ful for oxygen sensing applications where sensitivity to drift is important and where sample set ups must be left undisturbed for long periods of time The MFPF is used with Ocean Optics Fiber Optic Ox...

Page 10: ...es to 100 kHz It will give you lifetime measurements from 200 sec down to 0 3 sec The on board pressure transducer measures atmospheric pressure or external pressure with a inch hose fitting The MFPF...

Page 11: ...cessories You need Adobe Acrobat Reader version 6 0 or higher to view these files Ocean Optics includes the Adobe Acrobat Reader on the Software and Technical Resources CD Ocean Optics software requir...

Page 12: ...ition and display program that provides a real time interface to a variety of signal processing functions for users of Windows 95 98 ME NT 2000 XP OOISensors software supports USB2000 and USB4000 Spec...

Page 13: ...isplay program that provides a realtime interface to display and processing functions for use with Ocean Optics oxygen and pH sensors OOISensors acquires data for use by the MFPF software to convert d...

Page 14: ...ext The Select Program Manager Group screen appears 6 Select the name of the Program Manager group to which you want to add the OOISensor icons Then click Next The Start Installation dialog box appear...

Page 15: ...ING Ensure that the red plastic caps are covering the four SMA connectors on the front of the MFPF unit Intense UV radiation is emitted form the LEDS when the unit is powered up Do NOT look directly a...

Page 16: ...LED 1 red cap or place a piece of white paper in front of the LED if the red cap is not available Do NOT look directly at the light being emitted with the naked eye Caution Use only the power supply...

Page 17: ...1 Introduction MFPF Unit Rear Panel Once you have installed both the hardware and the software you must configure your system see Chapter 3 Configuration MFPF 00000 000 02 0606 9...

Page 18: ...2 Installation 10 MFPF 00000 000 02 0606...

Page 19: ...rt with the MFPF Software The MFPF unit uses a USB connection with an emulated RS232 port Before you are permitted to start the software you are asked to identify the COM port number of the emulated R...

Page 20: ...Click Device Manager 5 Scroll down and expand the Ports COM LPT list item 6 Note the port number assigned to the CP210x USB to UART device 7 Ensure that this is the COM port selected on the MFPF softw...

Page 21: ...e prompted to configure the software for use with your hardware Follow the steps below to configure OOISensors software Procedure 1 Run OOISensors If this is the first time you have opened the softwar...

Page 22: ...ware menu item 3 Double click on the icon on the desktop The main MFPF screen appears 4 Set the MFPF parameters located in the Instrument Controls box on the lower left of the main screen according to...

Page 23: ...ds on your experiment Detector Channel Depends on your experiment 5 Select Advanced Show More Control Panel from the menu bar The following dialog box appears 6 Set the parameters according to the fol...

Page 24: ...3 Configuration 16 MFPF 00000 000 02 0606...

Page 25: ...6 installation hardware 7 software 5 M MFPF configuring the COM port 11 front panel 8 models 2 overview 1 rear panel 9 O OOISensors configuring 13 P passwords 3 product related documentation iii R rec...

Page 26: ...Index 18 MFPF 00000 000 02 0606...

Reviews: