Chapter 1   

Setup 

Overview 

The following sections provide instructions on unpacking and setting up your Mini Deuterium Halogen 
Light Source (DT-Mini-2-GS). 

Before using the DT-Mini-2-GS for the first time, check for transport damage. Be sure to adhere to all 
warnings on the unit and in this manual. 

 

000-10000-110-02-0505 

1

 

Summary of Contents for DT-Mini-2-GS

Page 1: ...6 p m Fri EST Ocean Optics B V Europe Geograaf 24 6921 EW DUIVEN The Netherlands Phone 31 0 26 3190500 Fax 31 0 26 3190505 E mail Info OceanOptics com General sales inquiries Info OceanOpticsBV com European sales inquiries Orders OceanOptics com Questions about orders TechSupport OceanOptics com Technical support WARNING Protective Eye Wear Must Be Worn When Using This Instrument Intense Ultraviol...

Page 2: ... 2005 Ocean Optics Inc All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission from Ocean Optics Inc This manual is sold as part of an order and subject to the condition that it shall not by way of trade or otherwise be lent re sold hired out or ot...

Page 3: ...able parts inside 3 Only allow qualified personnel to service this unit 4 Do not use the unit if it is damaged in any way Contact your dealer for repair or replacement information 5 Always screw in the fiber optic cables before starting the instrument WARNING Protective eyewear must be worn when using this equipment Intense ultraviolet radiation present Never look directly into the light beam as t...

Page 4: ...Important Safety Notices B 000 10000 110 02 0505 ...

Page 5: ...ummary iii Product Related Documentation iii Upgrades iii Chapter 1 Setup 1 Overview 1 Unpacking the DT Mini 2 GS 2 Contents 2 Chapter 2 DT Mini 2 GS Specifications 3 Operating Environment 3 DT Mini 2 GS Components 3 Front Panel 4 Rear Panel 5 Appendix A Bulb Replacement 7 Replacing the Bulb 7 Index 9 000 10000 110 02 0505 i ...

Page 6: ...Table of Contents ii 000 10000 110 02 0505 ...

Page 7: ...ions for changing the bulb Product Related Documentation You can access documentation for Ocean Optics products by visiting our website at http www oceanoptics com Select Technical Operating Instructions then choose the appropriate document from the available drop down lists Or use the Search by Model Number field at the bottom of the web page You can also access operating instructions for Ocean O...

Page 8: ...About This Manual Authorization RMA number Please contact an Ocean Optics Application Scientist for specific instructions when returning a product iv 000 10000 110 02 0505 ...

Page 9: ...nstructions on unpacking and setting up your Mini Deuterium Halogen Light Source DT Mini 2 GS Before using the DT Mini 2 GS for the first time check for transport damage Be sure to adhere to all warnings on the unit and in this manual 000 10000 110 02 0505 1 ...

Page 10: ...e 2 Inspect the outside of the instrument and make sure that there is no damage Do not use the instrument if damage is present 3 Use this instrument in a clean laboratory environment Contents Your DT Mini 2 GS package should contain the following DT Mini 2 GS Mini Deuterium Halogen Light Source One IC DB15 2 interface cable for shutter operation 2 000 10000 110 02 0505 ...

Page 11: ... that its location or position does not interfere with proper ventilation Heat Should be situated away from any device that emits excessive heat Object and Liquid Entry Should be positioned so that objects do not fall on top of the unit Additionally ensure that no liquids are spilled into the enclosure through openings Power Sources Should be connected to a power supply only of the type described ...

Page 12: ...connector before starting the DT Mini 2 GS lamp Use caution when handling other end of the fiber optic cable to ensure that light radiation does not come into contact with skin and or eyes WARNING Protective eyewear must be worn when using this equipment Intense ultraviolet radiation present Never look directly into the light beam as this can cause eye damage SMA Connector Halogen ON OFF Shutter O...

Page 13: ...tion Lamp ON OFF TTL Switch When this switch is turned ON when the lamp has power you can operate the lamp by using the switches on the front panel Switch Position Function ON The deuterium and halogen bulbs are illuminated OFF The deuterium and halogen bulbs are not illuminated TTL The lamp is powered up and can be controlled by the SUB D connector Pin 1 Deuterium ON OFF Pin 5 Halogen ON OFF Pin ...

Page 14: ...2 DT Mini 2 GS Specifications 6 000 10000 110 02 0505 ...

Page 15: ... number DT Mini 2 B Replacing the Bulb Use the following procedure to replace the bulb Procedure 1 Remove the four screws on the bottom of the housing of the DT Mini 2 GS and remove the cover 2 Disconnect the four cables attached to the deuterium and halogen bulb 000 10000 110 02 0505 7 ...

Page 16: ...Mini 2 GS by gently pulling the bulb backwards out of the internal bulb socket Bulb Housing Screw Pull Gently Caution Do not turn or wiggle the bulb during removal as this can damage the bulb socket 5 Reverse the steps above to insert the new Mini D2 B into the bulb housing 8 000 10000 110 02 0505 ...

Page 17: ...ence iii purpose iii summary iii L Lamp ON OFF TTL Switch 5 O operating environment 3 P package contents 2 Power Input Connector 5 product related documentation iii S setup 1 SMA Connector 4 specifications 3 U unpacking procedure 2 upgrades iii W what s new iii 000 10000 110 02 0505 9 ...

Page 18: ...Index 10 000 10000 110 02 0505 ...