7.3.9 Replacing the pressure roller
A29246-X20-X-4-7680 / fa703.fm
323
Install pressure roller
Caution
Observe the safety directives before installing the pressure roller(
see section 7.3.9
Replacing the pressure roller, page 320)
.
Proceed as follows:
1.
Remove new pressure roller from the packaging.
Caution
The components in the fuser station reach a surface temperature of approximately
230
o
C in operation.
If you touch them, you may burn yourself.
Put on heat protection gloves to continue working.
2.
Put on heat protection gloves.
3.
Insert pressure roller carefully into the
fuser station from below and place in
the receptacles and hold there.
Close the locking pins on the right and
left sides.
4.
Swivel on the roller saddle until the
lock engages.