Océ ProCut Site Prep
Electrical connections - 400 V system with 2.2/2.55 kW vacuum pump (1600 M Only)
Comply with national instructions and laws at connection the cutter to the power supply system. The
cutter is connected with one power cord to the power supply system. The vacuum pump is
connected to the power box of the cutter. 1 power cord is included in the package content.
Figure 4: 400V Electrical Connection
“A” Cutter Power box
Value
Unit
Phases 3
Voltage 400
V
Power frequency, pump-depending
50/60
Hz
Power fusing min.
32
A
Wiring
3 phases, L1, L2, L3, N, PE
CEE-Plug 32A
Table 8: Electrical Connections with 2.2/2.55kW Vacuum Pumps
Electrical connections - 208 V system with 2.2/2.55 kW vacuum pump (1600 M Only
Comply with national instructions and laws at connection the cutter to the power supply system. The
cutter is connected with one power cord to the power supply system. The vacuum pump is
connected to the power box of the cutter. 1 power cord is included in the package content.
Figure 5: 200V Electrical Connection
“A” Cutter Power box
Value
Unit
Phases 3
Voltage 208
V
Power frequency, pump-depending
50/60
Hz
Power fusing min.
32
A
Wiring
3 phases, L1, L2, L3, N, PE
CEE-Plug 32A
Table 9: Electrical Connections with 2.2/2.55kW Vacuum Pumps
Océ ProCut Site Preparation Guide - Revision: E
8