Océ | System Requirements
2-8
3010102253-B
Current:......................8 AMPS maximum steady state
Power: .......................6kW max.
Circuit Breaker...........15 Amps
190 Volts @ 50 Hz
Voltage:......................190 VAC +/-10%, 3 Phase
Current:......................16.5 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........20 Amps
380 Volts @ 50 Hz
Voltage:......................380 VAC +/-10%, 3 Phase
Current:......................8 AMPS maximum steady state
Power: .......................7kW max.
Circuit Breaker...........15 Amps
ODGS recommends that the AC power outlet for the vacuum pump be located within 8
feet of the power inlet on the pump.
2.2.4
GFI Circuit Breakers
Due to the use of electromagnetic interference (EMI) filters required to meet conducted
radio frequency emission standards, the system is not compatible with ground fault
interrupting (GFI) circuit breakers. Use standard thermal circuit breakers where possible.
1
Important:
Unplugging the power cord from the wall socket is the only way to
isolate the entire machine.
Caution:
THE SOCKET OUTLET MUST BE INSTALLED NEAR THE EQUIPMENT
AND BE EASILY ACCESSIBLE.
ATTENTION: LE SOCLE DE PRISE DE COURANT DOIT ÊTRE
INSTALLÉ A PROXIMITÉ DU MATÉRIEL ET DOIT ÊTRE AISÉMENT
ACCESSIBLE.
VORSICHT: DIE STECKDOSE SOLLTE NAHE AN DER MASCHINE
UND BEGUEM ZUGÄNGLECH SEIN.
1. If standard thermal circuit breakers are used (standard in private homes and most office
environments, there is a potential for nuisance tripping of the breaker due to inrush currents
during equipment start-up. If this becomes a problem, we recommend the use of a breaker with
higher inrush current capabilities or a circuit breaker designed for thermal-magnetic operation.