Revision C (12/18) 

 

DANGER 

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH 

 

Turn off all power supplying equipment before working on or inside the equipment. 

 

Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes. 

 

This equipment must only be installed and serviced by qualified electrical personnel. 

 

Read, understand and follow the instructions before installing this product. 

 

Product may use multiple voltage/power sources. Be sure all sources of power have been disconnected 
before servicing. 

 

Use a properly rated voltage sensing device to confirm power is off. 

 

DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION 

 

Only install this product on insulated conductors. 

 

Failure to follow these instructions will result in death or serious injury. 

 

CAUTION 

This product is not intended for life or safety applications. 

 

Do not install this product in hazardous or classified locations. 

 

The installer is responsible for conformance to all applicable codes. 

 

Mount this product inside a suitable fire and electrical enclosure. 

 

A qualified person is one who has skills and knowledge related to the construction and operation of this 
electrical equipment, and the installation, and has received safety training to recognize and avoid the hazards 
involved. NEC2011 Article 100 No responsibility is assumed by Leviton for any consequences arising out of the 
use of this material. 

 

DO NOT EXCEED 346V Line to Neutral or 600 volts Line to Line. This meter is equipped to monitor loads 
up to 346V L-N. Exceeding this voltage will cause damage to the meter and danger to the user. Always 

use a Potential Transformer (PT) for voltages in excess of 346V L-N or 600 volts line to li

ne. The VerifEye™ is a 

600 Volt Over Voltage Category III device. 
 
For use in a Pollution Degree 2 or better environment only. A Pollution Degree 2 environment must control 
conductive pollution and the possibility of condensation or high humidity. Consider the enclosure, the correct 
use of ventilation, thermal properties of the equipment, and the relationship 
with the environment.   
Installation category: CAT II or CAT III 
 
Provide a disconnect device to disconnect the meter from the supply source. Place this device in close 
proximity to the equipment, and within easy reach of the operator, and mark it as the disconnecting device. 
The disconnecting device shall meet the relevant requirements of IEC 60947-1 and IEC 60947-3 and shall be 
suitable for the application. In the US and Canada, disconnecting fuse holders can be used. Provide 
overcurrent protection and disconnecting device for supply conductors with approved current limiting devices 
suitable for protecting the wiring. If the equipment is used in a manner not specified by the manufacturer, the 
protection provided by the device may be impaired. 
 

For the complete safety information for this product, see the full user guide. 

Summary of Contents for AcquiSuite Ally 12

Page 1: ...Revision C 12 18 AcquiSuite Ally 12 48 Advanced Multi Circuit Meter Install Guide...

Page 2: ...for any consequences arising out of the use of this material DO NOT EXCEED 346V Line to Neutral or 600 volts Line to Line This meter is equipped to monitor loads up to 346V L N Exceeding this voltage...

Page 3: ...output 200 mA self resetting fuse Waveform Sampling 1 8 kHz Parameter Update Rate 1 second Measurements Volts Amps kW kVAR kVA aPF dPF kW demand kVA demand Import Received kWh Export Delivered kWh Net...

Page 4: ...perating System Windows 7 Windows 8 Windows 10 Communications Port USB or Ethernet connectivity Safety FCC Compliance This device has been tested and found to comply with the limits for a Class A digi...

Page 5: ...Revision C 12 18 5 Mechanical Specifications Mounting Series AMC48 Enclosure Series AMC12 Enclosure...

Page 6: ...Revision C 12 18 6 Series AMC48 Enclosure Drill Pattern Series AMC12 Enclosure Drill Pattern...

Page 7: ...Revision C 12 18 7 Series AMC48 Mounting Plate Template...

Page 8: ...nd drill wall mounting points 2x 6x customer supplied The plastic enclosure itself can be used as a template for marking the drill locations on the wall If the meter is not available for use as a dril...

Page 9: ...Revision C 12 18 9 STEP 3 Mount conduit fittings conduits and blanking plugs STEP 4 Connect voltage leads...

Page 10: ...t the voltage leads L1 L2 L3 and N as necessary to the meter through a dedicated disconnect or circuit breaker A voltage lead of 14 AWG THHN Minimum 600VAC rating or equivalent is required IMPORTANT V...

Page 11: ...EXAMPLE LOADS Single Phase L1 N or L2 N 110 VAC Lighting Appliance Living Zone Single Phase L1 L2 220 VAC Water Heater Clothes Dryer Equipment with no neutral wire Split Phase L1 L2 220 VAC Service E...

Page 12: ...wire to this terminal If the neutral terminal is left open L L measurements will be accurate but L N measurements may not be symmetric If a ground wire is connected to the Neutral terminal 2mA will fl...

Page 13: ...hase service and configure each channel individually Three phase loads are illustrated on the left and split phase loads on the right as an example only Elements are fully interchangeable on the meter...

Page 14: ...Revision C 12 18 14...

Page 15: ...Contrast entry in the documentation indicates the active menu item in a list which corresponds to a blinking character in the physical LCD The ENTER button is used to select a property and up down but...

Page 16: ...ing supports accumulation of consumption data from any external meter using a dry contact Form A Relay or open collector outputs The AcquiSuite Ally pulse inputs are compatible with low speed meters T...