Obvius AcquiSuite A8810 Installation And Operation Manual Download Page 17

Networking

Network Status

This page displays the current status of the AcquiSuite network connections.  Several interfaces may be shown if both 
Ethernet and ppp dialin/dialout are active at the same time.  Each interface will report the ip address, number of packets sent 
and received, and other details specific to the interface.  For the ethernet interface, the MAC address (HWaddr) will be 
shown as well as a network collision count. 

Ethernet network

eth0      Link encap:Ethernet  HWaddr 00:99:99:0E:C1:CA  

          inet addr:192.168.10.50  Bcast:192.168.10.255  Mask:255.255.255.0

          UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1

          RX packets:2624171 errors:6 dropped:0 overruns:0 frame:0

          TX packets:220342 errors:0 dropped:0 overruns:0 carrier:0

          collisions:1 txqueuelen:100 

          RX bytes:174674347 (166.5 Mb)  TX bytes:50607122 (48.2 Mb)

          Interrupt:5 Base address:0x320 

Note: the “lo” or Loopback interface is the internal network and is always present, “eth0” is the Ethernet segment, and 
“ppp0” is the dialout or dialin connection.  In addition, the current gateway and DNS server information will be shown.  
These items will provide information about DHCP assigned configuration information.

Ethernet setup

The ethernet setup page has the following options:

IP Address: The ip address of the ethernet interface: Default 192.168.40.50

Netmask: The netmask of the ethernet network.  Default 255.255.255.0

Gateway Address: The gateway is the routing device that moves traffic from the LAN to the internet.  The default is 
192.168.40.1.  If you do not have an internet connection for your lan, or you are using a crossover ethernet cable, leave 
this field blank.

DNS 1, DNS2: These are the primary and secondary DNS servers.  If you are using a dialout connection, these must be 
set to the DNS server provided by your dialup isp.  If you only use the AcquiSuite on a crossover cable and/or dialin 
mode, you should leave these blank. 

DHCP (enable/disable)  If you LAN has a DHCP server, you may enable this option and remove the previous options for 
IP, netmask, gateway, and DNS.  Check with your LAN administrator first. 

HTTP Proxy.  If your LAN is connected to the internet using a sophisticated firewall, you may need to use the HTTP 
proxy feature.  Check with your LAN administrator first, however if you don't have a proxy set on your computer 
(MSIE/Tools/Connections-tab/LAN-Settings) then you most likely don't need to configure the AcquiSuite to use a proxy. 
If in doubt, leave this blank first, and try the connection test.  If it fails, ask your LAN administrator about proxy servers, 
if any. 

After changing any of the settings on this page, you will be required to reboot the AcquiSuite  Use the system/status web 
configuration page, or the LCD console to reboot the AcquiSuite.

Troubleshooting Ethernet Problems

After reconfiguring the ethernet settings you experience problems accessing the AcquiSuite with your web browser, check 
the following items.

Verify that you rebooted the AcquiSuite after making the changes to the network settings.

Use the AcquiSuite LCD console.  Check the IP address and Netmask.  Verify these are correct.

Verify the ethernet link/act light next to the Ethernet port is on.  It should blink with activity.

Verify the network connection in your computer has the proper IP address, on the same subnet, to access the AcquiSuite.  
NOTE: one common mistake is configuring the Laptop IP to the same address as the IP address of the AcquiSuite.  In 
order for the laptop and AcquiSuite to communicate, the IP addresses should not be identical. (see the basic network 
config for suggested IP addresses. )

Page 19

A8810 AcquiSuite – Data Acquisition Server

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for AcquiSuite A8810

Page 1: ...quisition Server Obvius LLC Installation and Operation Manual Model A8810 Date Jan 15 2013 Page 1 A8810 AcquiSuite Data Acquisition Server www GlobalTestSupply com Find Quality Products Online at sale...

Page 2: ...repaired altered or modified outside of Obvius s authorized facilities 4 has not been sold subject to other warranty terms specified at the time of sale and 5 is still owned by the original purchaser...

Page 3: ...Troubleshooting Ethernet Problems 19 System Options 20 Status 20 Processes 20 Date and Time 20 Universal Time Is Your Friend 20 System logs 21 Firmware Update 21 Diagnostics 22 Host Lookup 22 Connecti...

Page 4: ...long RS485 runs over 200ft LAN information Ethernet 10 100Mbit connection point hub or switch IP address and Netmask check with system administrator Gateway address check with system administrator DN...

Page 5: ...The RJ45 Ethernet is isolated to 1500VDC from the main board RS485 port is isolated to 1500VDC from the main board Power input and USB port and are non isolated Environmental Pollution Degree 2 Altit...

Page 6: ...e a minimum insulation rating that exceeds the voltage inside the panel In addition other regulations may apply consult the building codes in your area prior to installation The RS485 port on the A881...

Page 7: ...f when not connected Blinks when Lan traffic is being sent or received RS485 RX TX The 485TX led should blink slowly once per second during normal operation The RX led will blink when external Modbus...

Page 8: ...computer such as a laptop primary connection will be dialin or dialout by modem You will need the following information from your network administrator The addresses will be in the form of where refer...

Page 9: ...t to allow the AcquiSuite to reboot Once the AcquiSuite has rebooted the new IP address will be displayed on the console If DHCP addressing was specified the server assigned address will be displayed...

Page 10: ...tton B In the network setup dialog there should be a list of items including adapters clients and protocols Locate the item labeled Internet Protocol TCP IP Note If you have multiple ethernet cards yo...

Page 11: ...These include the 4 20mA device scale multipliers and engineering units Each 4 20mA or 0 10Vsensor should be supplied with technical information including the low and high range values that can be use...

Page 12: ...number and firmware version when available for all devices in the Modbus device list Show stats show packet counters for all devices in the device list These include Sent Total number of packets sent...

Page 13: ...Alarm Specify a threshold for the alarm If the data point is recorded below the Low Alarm or above the High Alarm levels at the time a log entry is taken the point will be considered in an alarm stat...

Page 14: ...he log period is not calculated based on 15 minutes after the last reading When the AcquiSuite is first started it will take an initial reading of all the Modbus devices immediately Following that the...

Page 15: ...for Modbus RS485 Devices This option allows the AcquiSuite to search for Modbus devices attached on the RS 485 port This feature may be disabled to reduce queries on the RS 485 port Default is enabled...

Page 16: ...sensor s serial number Each sensor may be given a name and some have additional options to configure such as input value scaling ModHopper Map The AcquiSuite has additional diagnostic features that a...

Page 17: ...server provided by your dialup isp If you only use the AcquiSuite on a crossover cable and or dialin mode you should leave these blank DHCP enable disable If you LAN has a DHCP server you may enable...

Page 18: ...synchronization will align the clock to within 1 second of the internet time source or atomic clock You may need to verify if your firewall will allow NTP or Rdate packets to pass through Generally i...

Page 19: ...ion log This log shows a list of files transferred by FTP on the AcquiSuite Last Data Upload log This log file contains a report from the last data upload attempt to remote database webservers such as...

Page 20: ...s will be printed in Green failure messages will be printed in Red A sample upload test follows Ping localhost 127 0 0 1 Success Ethernet IP address 192 168 10 50 mask 255 255 255 0 Local subnet 192 1...

Page 21: ...e cursor to the right one space If you press the select button multiple times the cursor will move right a similar number of spaces allowing you to skip over characters that may be correct based on th...

Page 22: ...rds that have been configured and will return the AcquiSuite to the factory default settings This is mainly useful when reconfiguring an AcquiSuite that has been used previously on a different job or...

Page 23: ...he log file but may be several seconds after the initial log cycle The log date time is in Universal time UTC This means that the data is logged with no shift for daylight savings time and must be con...

Page 24: ...lid data point Log Storage Capacity The AcquiSuite uses approximately 8 Mbytes of flash disk for log file storage As data from the modbus meters is collected it is appended to log files on this flash...

Page 25: ...on as needed Note if configuration changes are made to the AcquiSuite those changes will be uploaded to the BMO site If configuration changes are made at both the AcquiSuite and the BMO website the mo...

Page 26: ...on your computer as well as provide configuration information about the AcquiSuite Enertrax DL can also be configured to make LAN or Dilaup calls to one or more AcquiSuite or AcquiLite data acquisiti...

Page 27: ...ify a command prompt prior to using mdel that will prevent the FTP client software from asking if you are sure you wish to delete each file Linking to AcquiSuite Device Status Pages It may be helpful...

Page 28: ...y 4 x 4 25 x 2 deep The AcquiSuite has 4 mounting holes for use with a 6 screw The drawing above shows the relative position of the mounting holes Page 30 A8810 AcquiSuite Data Acquisition Server www...

Reviews: