Check Equipment
Inspect equipment. File claim with shipping company prior to
installation if shipment is damaged or incomplete.
Location
All wiring must comply with national, local, and state codes.
Wall Control
The Observer® Control is the command center for the com-
municating system. It should be located where it is easily
accessible and visible to the adult homeowner or end user.
For accurate temperature measurement, the following
guidelines should be followed:
The Observer Control and Room Sensors
SHOULD
be
mounted:
Approximately 5-ft (1.5 m) from the floor.
Close to or in a frequently used room, preferably on an inside
partitioning wall.
On a section of wall without pipes or ductwork.
The Observer Control and Room Sensors
SHOULD NOT
be
mounted:
Close to a window, on an outside wall, or next to a door lead-
ing to the outside.
Exposed to direct light or heat from a lamp, sun, fireplace, or
other temperature-radiating objects which could cause a false
reading.
Close to or in direct airflow from supply registers.
In areas with poor air circulation, such as behind a door or in
an alcove.
Summary of Contents for TSTAT0201CW
Page 12: ...12 616 01 1019 00 A14558 2 Press under All Days then press EDIT...
Page 20: ...20 616 01 1019 00 3 90 5 20 0 97 Fig 2 Wall Control Assembly Pieces...
Page 25: ...25 616 01 1019 00...
Page 65: ...65 616 01 1019 00 Zones...
Page 76: ...76 616 01 1019 00...
Page 77: ...77 616 01 1019 00...
Page 78: ...78 616 01 1019 00...