   PAGE 8

OBLICA

 | SPECIFICATIONS AND PRODUCT GUIDE

ACCESS

PANEL

FIRE

6.  ACCESS PANEL

Access panels are recommended for all ORTAL fireplaces. They allow efficient and 
comfortable access to the fireplace receiver and valves, which is required for servicing 
purpose. 
Access panels can designed and positionned to minimise their visual impact as long as 
access to the valves and receiver is maintained. The size of the access panel may vary, 
but in all cases must allow the fireplace technician to effectively conduct a services. We 
recommend a minimum size of 200x200mm. 

However, access panels are not the only option for servicing the fireplace operation 
mechanisms. A technician may also service the fireplace controls by going through the 
firebox. This procedure requires removing the glass panel(s), taking out the interior 
media and lifting the grill, burner and bottom side (explosion valve) of the unit. The 
technician would then return all these fireplace components when service is complete. 
The servicing procedure will take longer than through an access panel.

Fireplace installers are advised to consult with their clients, project architects or interior 
designers regarding the advantages and disadvantages of each service option. 

Summary of Contents for ORTAL 110

Page 1: ...ORTAL SINGLE SIDED FIREPLACES SPECIFICATIONS PRODUCT GUIDE ...

Page 2: ...pproved DuraVent flue system as specified Consult the relevant authority to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure that this fireplace is installed in compliance with the manufacturer s instructions and all the applicable building codes Contact your local distributor dealer for correct flue and flue termination informa...

Page 3: ...ith 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm TRAD 110 B100 Marked 1200 with 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm 130 130H B100 Marked 1200 with 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm 150 150H B135 Marked 1200 with 7x1 275mm orifice Marked 1400 with single 3 9mm orifice 55MJ h 1 13kPA 0 61kPA 0 22kPA 125 205mm 170 170H B135 Marked 1200 wit...

Page 4: ...68 130 1368 420 692 1278 x 350 130 H 1368 420 892 1278 x 550 150 1636 420 692 1528 x 350 150 H 1636 420 892 1528 x 550 170 1813 420 692 1528 x 350 170 H 1813 420 892 1528 x 550 200 2076 420 692 1968 x 350 200 H 2076 420 892 1968 x 550 250 2550 420 692 2444 x 400 250 H 2550 420 892 2444 x 550 Note Minimum height off of the floor for all front facing Ortal fireplaces is 210mm Appliance legs must not...

Page 5: ...0H 254 2683 475 915 TR90 254 1170 689 978 TR110 254 1360 689 1059 CLADDING FOR METAL STUDS external cladding The framing structure must be clad externally with non combustible material and gaps sealed with a non combustible fire proof sealant We recommend the fireplace to be in position and flued prior to cladding OPTION 1 METAL STUDS FRAMING Preferred option The frame must be designed to carry th...

Page 6: ...60 689 1059 662 CLADDING FOR TIMBER STUDS WITH METAL SECTION external cladding internal cladding OPTION 2 TIMBER STUDS WITH METAL SECTION The frame must be designed to carry the entire weight of the finished wall with no component being supported by the fireplace The framing structure must be clad internally and externally with non combustible material and gaps sealed with a non combustible fire p...

Page 7: ...T EXHAUST AND AIR INTAKE HOT AIR FLOW HEAT RELEASE AS REVEAL VENTING Convection air outlet A convection air outlet is required for all Ortal fireplaces This allows for heat building up within the fireplace cavity to be released back into the space helping to keep the cavity walls cool It must be located at the top of the fireplace cavity and be placed at a maximum of 150mm below the cavity ceiling...

Page 8: ...ervices We recommend a minimum size of 200x200mm However access panels are not the only option for servicing the fireplace operation mechanisms A technician may also service the fireplace controls by going through the firebox This procedure requires removing the glass panel s taking out the interior media and lifting the grill burner and bottom side explosion valve of the unit The technician would...

Page 9: ...PAGE 9 OBLICA SPECIFICATIONS AND PRODUCT GUIDE 7 TV CLEARANCES 305mm MIN 305mm MIN RECESSED INSTALLATION FLUSH INSTALLATION ...

Page 10: ...TAL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA IAPMO R T FOR USE WITH NATURAL GAS NG Australian Standard AS5263 0 2016 Decorative Gas Log and Other Fuel Effect Appliances Patent Pending for screen barrier glass bracket USSN 60 040 074 ...

Reviews: