5. VENTING
VENTING (convection air intake)
For mesh units:
- No need to create a convection air intake as the appliance is designed to supply fresh
air though the viewing panel.
For double glass units:
- Convection air intake vents are required at the bottom of the cavity and can be placed
at the front, side or back of the cavity.
SCREEN HEAT BARRIER -
GAP HEAT RELEASE
DOUBLE GLASS HEAT BARRIER -
REVEAL HEAT RELEASE
AIR INTAKE AS
REVEAL/TOE KICK
DIRECT VENT
EXHAUST AND
AIR INTAKE
HOT AIR FLOW
HEAT RELEASE
AS REVEAL
VENTING (Convection air outlet)
A convection air outlet is required for all Ortal fireplaces. This allows for heat building up within the fireplace cavity to
be released back into the space, helping to keep the cavity walls cool. It must be located at the top of the fireplace cavity
and be placed at a maximum of 150mm below the cavity ceiling. The vent can be located on the front, sides or back of
the fireplace cavity, as long as it releases into an interior space and not outdoors.
These are minimum requirements and the surface can be greater if desired.
MODEL
Heat release vent
(min surface)
60 to 130
0.08m
2
150 to 200
0.13m
2
250
0.16m
2