OBID i-scan
®
Installation
ID ISC.LRU2000
FEIG ELECTRONIC GmbH
Page 45 of 56
M60801-0de-ID-B.doc
E N G L I S H
2.8 External diagnostic LED connections
X14 allows for connection of additional external LEDs in parallel with the internal diagnostic LEDs.
The external LEDs are connected as shown in Fig. 2-9.
Terminal
Abbreviation
Description
1
V1
Anode ext.
Function same as internal LED V1
2
V2
Anode ext.
Function same as internal LED V2
3
V3
Anode ext.
Function same as internal LED V3
4
V4
Anode ext.
Function same as internal LED V4
5
V5
Anode ext.
Function same as internal LED V5
6
GND
Common GND
Table 2-10: External LED pin-outs
V4
V3
V2
V1
1
2
3
X14
3
1
5
4
X14
2
6
V5
V6
X14
S1
T1
ACC-Modul
external LEDs
V5
6
4
5
Fig. 2-9: Connecting external LEDs to X14
Note:
•
The outputs on X14 are intended for switching an external LED only. Overloading the
outputs with other loads may destroy them.