2.7 Inputs 

Outputs

2.7.1 Optocouplers

The optocouplers on Terminal X6 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.

Terminal

Abbreviation

Description

1

O-C

Collector – Output 1

2

O-E

Emitter – Output 1

3

IN+

+ Input 1

4

IN-

- Input 1

Table 2-6: Optocoupler pin-outs

2

1

3

4

X6

U

ext.

IN+

IN-

R

ext

R

int

O-C

O-E

U

ext.

Fig. 2-6: Internal and possible external wiring of the optocouplers

Summary of Contents for i-scan ID ISC.LRMU2000-B-EU

Page 1: ...MONTAGE INSTALLATION final public B 2006 09 03 M60801 0de ID B doc OBID i scan ID ISC LRU2000 deutsch english ...

Page 2: ...OBID i scan Montage ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 2 von 56 M60801 0de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 30 E N G L I S H ...

Page 3: ...welches die in diesem Dokument be schriebenen Geräte enthält FEIG ELECTRONIC weist ausdrücklich darauf hin dass die in diesem Dokument beschriebenen Geräte nicht für den Einsatz mit oder in medizinischen Geräten oder für Geräte für lebenserhaltende Maßnahmen konzipiert sind bei denen ein Fehler eine Gefahr für menschliches Leben oder für die gesundheitliche Un versehrtheit zur Folge haben kann Der...

Page 4: ...en des Deckels 10 2 4 Anschlussklemmen 11 2 5 Antennenanschluss 12 2 6 Versorgungsspannung 12 2 7 Eingänge Ausgänge 13 2 7 1 Optokoppler 13 2 7 2 Relais 15 2 7 3 Readersynchronisation 16 2 8 Anschluss externer Diagnose LEDs 17 2 9 Schnittstellen 18 2 9 1 RS232 Schnittstelle 18 2 9 2 RS485 RS422 Schnittstelle 19 2 9 3 Netzwerkanschluss 20 2 9 4 CompactFlash Steckplatz nur Gerätevarianten mit ACC 20...

Page 5: ... i scan Montage ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 5 von 56 M60801 0de ID B doc D E U T S C H 4 1 2 Netzwerkanschluss LAN 25 5 Funkzulassungen 26 5 1 Europa CE 26 5 2 USA FCC 26 6 Technische Daten 27 ...

Page 6: ...hrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gültigen Fassung Für eine ungeeignete falsche manuelle oder automatische Ein stellung von Parametern für ein Gerät bzw ungeeignete Verwendung eines Gerätes wird keine Haftung übernommen Reparaturen dürfen nur vom Hersteller durchgeführt werden Anschluss Inbetriebnahme Wartungs und sonstige Arbeiten am Gerät dürfen nur von Elekt...

Page 7: ...adertypen Folgende Reader und Readermodule sind z Z verfügbar Readertyp Beschreibung ID ISC LRU2000 A EU Gerätevariante mit ACC für Europa ID ISC LRU2000 A FCC Gerätevariante mit ACC für USA ID ISC LRU2000i A EU Gerätevariante mit ACC und interner Antenne für Europa ID ISC LRU2000i A FCC Gerätevariante mit ACC und interner Antenne für USA Tabelle 2 1 Readertypen Readermodultyp Beschreibung ID ISC ...

Page 8: ...RONIC GmbH Seite 8 von 56 M60801 0de ID B doc D E U T S C H 2 3 Montage Der Reader ist für die Montage auf Wänden auch im Freien konzipiert Zur Wandmontage befin den sich im Gehäuse vorgesehene Löcher Bild 2 1 Montagezeichnung 316 300 5 161 180 90 ...

Page 9: ...ngen für die einzelnen Leitungen verwendet werden sollen 2 1 3 9 5 8 4 6 7 Bild 2 2 Montagezeichnung Kabelver schraubung Größe Klemmbereich mm Beschreibung 1 M 16 4 5 10 Anschlusskabel Antenne 2 M 16 4 5 10 Anschlusskabel Antenne 3 M 16 4 5 10 Anschlusskabel Antenne 4 M 16 4 5 10 Anschlusskabel Antenne 5 M 12 3 5 7 Spannungsversorgung 6 M 16 4 5 10 Ein Ausgänge Schnittstelle 7 M 16 4 5 10 Ein Ausg...

Page 10: ... ID ISC LRU2000 FEIG ELECTRONIC GmbH Seite 10 von 56 M60801 0de ID B doc D E U T S C H 2 3 2 Öffnen des Deckels In Bild 2 3 Öffnen des Deckels ist dargestellt wie sich das Gehäuse öffnen lässt Bild 2 3 Öffnen des Deckels ...

Page 11: ...e 11 von 56 M60801 0de ID B doc D E U T S C H 2 4 Anschlussklemmen J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD X12 ACC X20 X1 X2 X3 X4 X6 X7 X8 V5 V4 V3 V2 V1 COM NO VDC GND Bild 2 4 Anschlussklemmen des Readers ...

Page 12: ...kers Klemme Beschreibung X1 X2 X3 X4 Anschluss der externen Antennen Eingangsimpedanz 50Ω Tabelle 2 4 Anschluss der externen Antenne 2 6 Versorgungsspannung Die Versorgungsspannung von 15 bis 24 VDC ist an der Klemme X13 anzuschließen Klemme Kurzzeichen Beschreibung X13 Pin 1 VDC Vcc Versorgungsspannung X13 Pin 2 GND Ground Versorgungsspannung Tabelle 2 5 Pinbelegung Versorgungsspannung X13 GND VD...

Page 13: ...e X6 sind galvanisch von der Reader Elektronik getrennt und müs sen daher mit einer externen Spannung versorgt werden Klemme Kurzzeichen Beschreibung 1 O C Kollektor Ausgang 1 2 O E Emitter Ausgang 1 3 IN Eingang 1 4 IN Eingang 1 Tabelle 2 6 Pinbelegung Optokoppler 2 1 3 4 X6 Uext IN IN Rext Rint O C O E Uext Bild 2 6 Interne und mögliche externe Beschaltung der Optokoppler ...

Page 14: ...asten vorgesehen Optokopplereingang X6 3 4 Die Eingangs LED des Optokopplers ist intern mit einem Serienwiderstand von 500 Ω beschaltet Bei Versorgungsspannungen größer 10V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand siehe Tabelle 2 7 auf max 20 mA begrenzt werden Tabelle 2 7 zeigt die benötigten externen Vorwiderstande bei den verschiedenen externen Span nungen Uext Externe...

Page 15: ...M Arbeitskontakt 2 NC Öffner 3 NO Schließer Tabelle 2 8 Pinbelegung Relaisausgang Hinweise Der Relaisausgang ist für max 24 V DC 2 A ausgelegt Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen Im Falle einer induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu schüt zen ext U 1 2 3 X9 COM NO NC Bild 2 7 Interne und mögliche externe Beschaltung des Relaisa...

Page 16: ...onisation Mit der Readersynchronisation können verschiedene Aktionen der Reader synchronisiert werden Klemme Kurzzeichen Beschreibung 1 GND GND 2 A Eingang 3 B Eingang 4 Y Ausgang 5 Z Ausgang Tabelle 2 9 Pinbelegung Readersynchronisation 1 2 3 4 5 OUT Z OUT Y IN B IN A GND X5 Bild 2 8 Eingang und Ausgang der Synchronisation ...

Page 17: ...er LED V1 2 V2 Anode ext Funktion entspricht interner LED V2 3 V3 Anode ext Funktion entspricht interner LED V3 4 V4 Anode ext Funktion entspricht interner LED V4 5 V5 Anode ext Funktion entspricht interner LED V5 6 GND Gemeinsamer GND Anschluss Tabelle 2 10 Pinbelegung externe LEDs 1 3 5 6 4 2 6 5 4 3 2 1 V1 V2 V3 V4 V5 Externe LEDs ACC Modul X14 V5 V6 S1 T1 X14 X14 Bild 2 9 Anschluss externer LE...

Page 18: ... über X8 Die Übertragungsparameter können per Softwareprotokoll konfiguriert werden Anschlussbelegung X8 RS232 Schnittstelle Klemme Kurzzeichen Beschreibung 1 GND RS232 GND 2 RxD RS232 RxD 3 TxD RS232 TxD Tabelle 2 11 Pinbelegung RS232 Schnittstelle PC X8 3 Pin 2 X8 2 Pin 3 X8 1 Pin 5 9 pol D SUB Buchse X8 TxD RxD GND 3 2 1 Bild 2 10 Verdrahtungsbeispiel für den Anschluss der RS232 Schnittstelle ...

Page 19: ...1 Schnittstellenkonfiguration mittels Jumper Der Anschluss der RS4xx Schnittstelle erfolgt über X7 Anschlussbelegung X7 RS485 RS422 Schnittstelle Klemme Kurzzeichen Beschreibung 1 GND RS485 RS422 GND 2 A RS485 RS422 A 3 B RS485 RS422 B 4 Y RS422 Y 5 Z RS422 Z Tabelle 2 12 Pinbelegung RS485 RS422 Schnittstelle RS422 Z RS422 Y 5 RS485 RS422 A RS485 RS422 GND RS485 RS422 B 1 2 4 3 X7 Bild 2 11 Anschl...

Page 20: ...r Kategorie 5 verwendet werden Dies garan tiert einen problemlosen Betrieb bei 10Mbps oder 100Mbps Anschlussbelegung X8 Netzwerk Schnittstelle Klemme Kurzzeichen Beschreibung 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 4 VETH n c 5 VETH n c 6 RX Receive Data 7 VETH n c 8 VETH n c Tabelle 2 13 Pinbelegung Ethernet Schnittstelle 2 9 4 CompactFlash Steckplatz nur Gerätevarianten mit ACC D...

Page 21: ...Reset im Anschluss an ein Software Update Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten fehler beim Lesen der Parameter auftrat LED V3 gelb Diagnose 2 Host Kommunikation Signalisiert durch ein kurzes Blinken das Senden eines Proto kolls an den Host auf der RS232 RS485 Schnittstelle LED V4 gelb Reserviert LED V5 rot Diagnose 4 RF Warnung Leuchtet während der Reader Initialisierung nach...

Page 22: ...B doc D E U T S C H 3 2 Taster Schalter Kurzzeichen Beschreibung T1 Reset Taster RF Controller T2 Reset Taster ACC S1 Reserviert Tabelle 3 2 Taster Schalter T1 Durch betätigen von T1 wird am RF Controller ein Reset durchgeführt T2 Durch betätigen von T2 wird am ACC ein Reset durchgeführt ...

Page 23: ...uration der RS485 RS422 Schnitstelle Es können die eventuell benötigten Abschlusswiderstände mit den Jumpern J1 bis J6 zugeschaltet werden Jumper Geschlossen offen J1 Pull Up an RS4xx B ohne Pull Up an RS4xx B J2 Pull Down an RS4xx A ohne Pull Down an RS4xx A J5 Abschlusswiderstand RS4xx A RS4xx B ohne Abschlusswiderstand RS485 A RS485 B J3 Pull Up an RS422 Z ohne Pull Up an RS422 Z J4 Pull Down a...

Page 24: ...nittstelle Bild 4 2 Jumper der RS422 Schnittstelle J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X6 X7 Bild 4 3 Jumper der RS485 RS422 Schnittstelle Tabelle 4 3 zeigt die Standardkonfiguration der Jumper J9 bis J12 Diese sind für die RS485 und RS422 identisch Jumper LRU2000 Gerätevarianten mit ACC LRU2000 Gerätevarianten ohne ACC J9 Geschlossen offen J10 Geschlossen Geschlossen J11 offen offen J12 offen ...

Page 25: ...r werksseitig die Adresse 0 eingestellt haben müssen sie nacheinander ange schlossen und konfiguriert werden 4 1 2 Netzwerkanschluss LAN Vorraussetzung für den Einsatz des TCP IP Protokolls ist dass jedes Gerät am Netzwerk über eine eigene IP Adresse verfügt Alle Reader verfügen über eine werksseitig voreingestellte IP Adresse Die Reader müssen nacheinander ans Netzwerk angeschlossen und konfiguri...

Page 26: ...akische Republik Slovenien Spanien Schweden Niederlande Türkei Großbritan nien Frequenzbereich nicht implementiert Estland Individuelle Lizenz benötigt Bei Betrieb im Band I nach ERC REC 70 03 Annex 1 869 400MHz 869 650MHz gelten folgen de Einschränkungen für Stand Juli 2006 Bulgarien Frequenzbereich nicht implementiert Italien max 25 mW e r p Slovakische Republik max 10 mW e r p 5 2 USA FCC FCC I...

Page 27: ...pple max 150 mV Leistungsaufnahme max 30 VA Betriebsfrequenz 869 525 MHz EN 300 220 865 6 867 6MHz EN 302 208 902 928MHz FCC CFR 47 Part 15 247 Sendeleistung 100 mW 3 W 100 mW Step Software 4 W EIRP FCC CFR 47 Part 15 247 2 W ERP EN 302 208 0 5Watt ERP EN 300 220 Modulationsgrad 20 40 und 100 per Software einstellbar Empfänger Datenraten 40 320 kbps Antennenanschlüsse 4 x gemultiplext 4 x SMA Buch...

Page 28: ...Reader Mode Data Filtering and buffe ring Unterstützte Transponder 18000 6 B EPC class 1 gen 1 EPC class 1 gen 2 Signalgeber optisch 6 LEDs zur Diagnose des Betriebszustandes Umgebungsbedingungen Temperaturbereich Betrieb Lagerung 25 C bis 55 C 25 C bis 70 C 25 C bis 85 C Vibration EN60068 2 6 10 Hz bis 150 Hz 0 075 mm 1 g Schock EN60068 2 27 Beschleunigung 30 g Angewendete Normen Zulassung Funk E...

Page 29: ......

Page 30: ... the subject of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a hum...

Page 31: ...ds 36 2 3 2 Opening the cover 37 2 4 Terminals 38 2 5 Antenna connection 39 2 6 Supply voltage 40 2 7 Inputs Outputs 41 2 7 1 Optocouplers 41 2 7 2 Relay 43 2 7 3 Reader synchronization 44 2 8 External diagnostic LED connections 45 2 9 Interfaces 46 2 9 1 RS232 interface 46 2 9 2 RS485 RS422 interface 47 2 9 3 Network connection 48 2 9 4 CompactFlash Slot only device version with ACC 48 3 Operatin...

Page 32: ... scan Installation ID ISC LRU2000 FEIG ELECTRONIC GmbH Page 32 of 56 M60801 0de ID B doc E N G L I S H 4 1 2 Network connection LAN 53 5 Radio Approvals 54 5 1 Europe CE 54 5 2 USA FCC 54 6 Technical Data 55 ...

Page 33: ...iptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should o...

Page 34: ...ader types The following Readers are currently available Reader type Description ID ISC LRU2000 A EU Device version with ACC for Europe ID ISC LRU2000 A FCC Device version with ACC for USA ID ISC LRU2000i A EU Device version with ACC and internal antenna for Europe ID ISC LRU2000i A FCC Device version with ACC and internal antenna for USA Table 2 1 Reader types Reader module type Description ID IS...

Page 35: ... ELECTRONIC GmbH Page 35 of 56 M60801 0de ID B doc E N G L I S H 2 3 Installation The Reader is designed for wall mount including outdoors Holes for mounting on a wall are provided in the housing Fig 2 1 Installation drawing 316 300 5 161 180 90 ...

Page 36: ...indicates which cable glands should be used for the individual lines 2 1 3 9 5 8 4 6 7 Fig 2 2 Installation drawing Cable gland Size Clamping range mm Description 1 M 16 4 5 10 Antenna cable 2 M 16 4 5 10 Antenna cable 3 M 16 4 5 10 Antenna cable 4 M 16 4 5 10 Antenna cable 5 M 12 3 5 7 Supply voltage 6 M 16 4 5 10 In Outputs Interface 7 M 16 4 5 10 In Outputs Interface 8 M 12 3 5 7 In Outputs Int...

Page 37: ...can Installation ID ISC LRU2000 FEIG ELECTRONIC GmbH Page 37 of 56 M60801 0de ID B doc E N G L I S H 2 3 2 Opening the cover Fig 2 3 Opening the cover shows how to open up the housing Fig 2 3 Opening the cover ...

Page 38: ...ONIC GmbH Page 38 of 56 M60801 0de ID B doc E N G L I S H 2 4 Terminals J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD X12 ACC X20 X1 X2 X3 X4 X6 X7 X8 V5 V4 V3 V2 V1 COM NO VDC GND Fig 2 4 Reader terminals ...

Page 39: ...a connection The external antenna is connected on the analog circuit board The maximum tightening torque for the SMA sockets is 0 45 Nm Caution Exceeding the tightening torque will destroy the plug Terminal Description X1 X2 X3 X4 Connection for external antennas input impedance 50Ω Table 2 4 External antenna connection ...

Page 40: ...ge The supply voltage of 15 to 24 VDC is connected to Terminal X13 Terminal Abbreviation Description X13 Pin 1 VDC Vcc supply voltage X13 Pin 2 GND Ground supply voltage Table 2 5 Pin outs for supply voltage X13 GND VDC 2 1 Fig 2 5 Connecting the supply voltage Note Reversing the supply voltage polarity may destroy the device ...

Page 41: ...rs on Terminal X6 are galvanically isolated from the Reader electronics and must therefore be externally supplied Terminal Abbreviation Description 1 O C Collector Output 1 2 O E Emitter Output 1 3 IN Input 1 4 IN Input 1 Table 2 6 Optocoupler pin outs 2 1 3 4 X6 Uext IN IN Rext Rint O C O E Uext Fig 2 6 Internal and possible external wiring of the optocouplers ...

Page 42: ...output is intended for switching resistive loads only Optocoupler input X6 3 4 The input LED associated with the optocoupler is connected internally to a series resistor of 500 Ω For supply voltages of greater than 10V the input current must be limited to max 20 mA by means of an additional series resistor see Table 2 7 Table 2 7 shows the necessary external resistors for various external voltages...

Page 43: ... COM Working contact 2 NC Normally closed 3 NO Normally open Table 2 8 Relay output pin outs Notes The relay output is configured for max 24 V DC 2 A The relay output is intended for switching resistive loads only If an inductive load is connected the relay contacts must be protected by means of an external protection circuit ext U 1 2 3 X9 COM NO NC Fig 2 7 Internal and possible external wiring o...

Page 44: ... 2 7 3 Reader synchronization Reader synchronization can be used to synchronize various Reader actions Terminal Abbreviation Description 1 GND GND 2 A Input 3 B Input 4 Y Output 5 Z Output Table 2 9 Reader synchronization pin outs 1 2 3 4 5 OUT Z OUT Y IN B IN A GND X5 Fig 2 8 Synchronization input and output ...

Page 45: ...Anode ext Function same as internal LED V1 2 V2 Anode ext Function same as internal LED V2 3 V3 Anode ext Function same as internal LED V3 4 V4 Anode ext Function same as internal LED V4 5 V5 Anode ext Function same as internal LED V5 6 GND Common GND Table 2 10 External LED pin outs V4 V3 V2 V1 1 2 3 X14 3 1 5 4 X14 2 6 V5 V6 X14 S1 T1 ACC Modul external LEDs V5 6 4 5 Fig 2 9 Connecting external ...

Page 46: ...ected on X8 The transmission parameters can be configured by means of software protocol Pin configuration X8 RS232 interface Terminal Abbreviation Description 1 GND RS232 GND 2 RxD RS232 RxD 3 TxD RS232 TxD Table 2 11 RS232 interface pin outs X8 3 X8 2 X8 1 Pin 2 Pin 5 Pin 3 9 pol D SUB Jack 1 2 3 X8 TxD RxD GND PC Fig 2 10 Wiring example for connecting the RS232 interface ...

Page 47: ... see Section Interface configuration The RS485 RS422 interface is connected on X7 Pin configuration X7 RS485 RS422 interface Terminal Abbreviation Description 1 GND RS485 RS422 GND 2 A RS485 RS422 A 3 B RS485 RS422 B 4 Y RS422 Y 5 Z RS422 Z Table 2 12 RS485 RS422 interface pin outs RS422 Z RS422 Y 5 RS485 RS422 A RS485 RS422 GND RS485 RS422 B 1 2 4 3 X7 Fig 2 11 Wiring example for the RS485 RS422 ...

Page 48: ...structured cabling Cat 5 cables should be used This ensure reliable operation at 10Mbps or 100Mbps Pin configuration for X8 network interface Terminal Abbreviation Description 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 4 VETH n c 5 VETH n c 6 RX Receive Data 7 VETH n c 8 VETH n c Table 2 13 Ethernet interface pin outs 2 9 4 CompactFlash Slot only device version with ACC The Reader has...

Page 49: ...h V1 after a reset following a software update Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 yellow Diagnostic 2 Host communication Short flashing indicates sending of a protocol to the host on the RS232 RS485 interface LED V4 yellow Reserved LED V5 red Diagnostic 4 RF warning Comes on during Reader initialization after power on or after a res...

Page 50: ...GmbH Page 50 of 56 M60801 0de ID B doc E N G L I S H 3 2 Buttons Switches Abbreviation Description T1 RF Controller reset button T2 ACC reset button S1 Reserved Table 3 2 Buttons Switches T1 Pressing T1 resets the RF Controller T2 Pressing T2 resets the ACC ...

Page 51: ... RS485 RS422 port Any termination resistors needed can be enabled using jumpers J1 through J6 Jumper Closed Open J1 Pull Up on RS4xx B without Pull Up on RS4xx B J2 Pull Down on RS4xx A without Pull Down on RS4xx A J5 Termination resistor RS4xx A RS4xx B without Termination resistor RS485 A RS485 B J3 Pull Up on RS422 Z without Pull Up on RS422 Z J4 Pull Down on RS422 Y without Pull Down on RS422 ...

Page 52: ...A Fig 4 1 RS485 interface jumpers Fig 4 2 RS422 interface jumpers J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X6 X7 Fig 4 3 RS485 RS422 interface jumpers shows the standard configuration of jumpers J9 through J12 These are identical for RS485 and RS422 Jumper LRU2000 device version with ACC LRU2000 device version without ACC J9 closed open J10 closed closed J11 open open J12 open closed Table 4 3 Stand...

Page 53: ... Reader Note Since all Readers are factory set with address 0 they must be connected and configured one after the other 4 1 2 Network connection LAN The prerequisite for using TCP IP protocol is that each device has a unique address on the network All Readers have a factory set IP address The Readers must be connected and configured one after the other Table 4 4 shows the standard configuration of...

Page 54: ... Portugal Romania Slovak Republic Slovenia Spain Sweden The Neth erlands Turkey United Kingdom Operation not currently permitted Estonia Operation only with individual license When operating the ID ISC LRU2000 in Band I ERC REC 70 03 Annex 1 869 400MHz 869 650MHz the following restrictions apply Bulgaria Operation not currently permitted Italy max 25 mW e r p Slovak Republic max 10 mW e r p 5 2 US...

Page 55: ...Operating frequency 869 525 MHz EN 300 220 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Transmitting power 100 mW 3 W 100 mW Step Software 4 W EIRP FCC CFR 47 Part 15 247 2 W ERP EN 302 208 0 5 W ERP EN 300 220 Modulation 20 40 and 100 software configurable Receiver Data rates 40 320 kbps Antenna connections 4 x multiplexing 4 x SMA socket 50Ω Outputs 1 optocoupler 1 differential ...

Page 56: ...d buffering Supported transponders 18000 6 B EPC class 1 gen EPC class 1 gen 2 Optical indicators 6 LEDs for operating status diagnostics Ambient Temperature range Operating Storage 25 C to 55 C 25 C to 70 C 25 C to 85 C Vibration EN60068 2 6 10 Hz to 150 Hz 0 075 mm 1 g Shock EN60068 2 27 Acceleration 30 g Applicable standards RF approval Europe USA EN 302 208 EN 300 220 FCC 47 CFR Part 15 EMC EN...

Reviews: