Note6. % to be set when parameter VP Mode is "1".
Note13. Correspondence only in case of "Step-up" controll.
Note7. To be set when parameter VP Mode is "2".
Parameter Sheet
Timer No.
Item/Function
Display Letter
Setting Range/Information
Parameter
value
Pulsation Select
P1 Pulse. Sel.
ON :Enable OFF :Disable
A or B Mode Select
P2 AB Mode
ON :A Mode OFF :B Mode
Alarm signal NO/NC select
P3 ALM Out
ON :Normal Open OFF :Normal Close
Trigger start
P4 One Shoot
ON :Enable OFF :Disable
Hold End signal select
P5 Hold Out
ON :Enable OFF :Disable
Hold End Delay Job section
at alarm signal
P6 HoldA Dly
ON :Enable OFF :Disable
Alarm output signal select
P7 ALM Mode
0 :Alarm pulse output enable 1 :Alarm constant output enable
2 :Alarm constant output & weld stop 3 :Skip alarm output
Max. Step Up series select
P8 Step Type
0 :Disable 1 :Max. gun series 2 :4/15 series
Trigger SW priority select
P9 Sw mode
ON :Trigger SW priority select OFF :Weld sequence priority select
Japanese or English display
select
Pa Japanese
ON: Japanese OFF: English
Transformer turn ratio series
select
Pb TransType
0: 1 series 1: Max. gun series 2: 4/15 series
Repeat action select
Pc RepeatSel.
ON :Enable OFF :Disable
Reweld action select at
current low detected
Pd Reweld
ON :Enable OFF :Disable
Pressure adjustment select
Pe VP Mode
0 :Disable 1 :%Setting enable 2 :Direct number setting enable
3 :Direct number setting enable, and display only setting
Pressure adjustment control
voltage select
Pf VP Type
0 :control range 0-5V :control range:0-10V
caution output select
Pg Caution
ON :Enable OFF :Disable
Transformer
thermostat
check sequence
Ph Gun Chang.
ON :Enable(Check at weld start) OFF :Disable(Always check)
Alarm output signal select on
No-weld sequence
Pi TestW ALM
ON :Alarm output signal enable OFF :Alarm output signal disable
Max.
Gun
num.
select
Retract select Valve selector
select Weld interlock select
Pj Gun Sel.
00~08: Max. SOL valve select 11~18: Retract enable 21~28:
Reverse wire Retract enable 31~38: Valve selector enable 41~48:
Weld interlock enable 51~58: Retract & Retract interlock enable
61~68: Reverse wire Retract & Retract interlock enable
Step Up Max. value select
Pk Max Step
2~16: Step Up max. number select
Display level select
PL DispLevel
0: Display all function 1: Display limited function 2: Display limited
to 1group 3: Display limited to 4group
Step-dawn transformer
Pm Ref. Volt
0: 200V line voltage set 1: 220V line voltage set 2: 380V line
voltage set 3: 400V line voltage set 4: 420V line voltage set 5:
440V line voltage set 6: 460V line voltage set 7: 480V line voltage
set
Weld enable/disable select
Pn Test Mode
0: Weld enable (standard) 1: Weld disable 2: Weld disable & sol.
valve control 3: Cable short check enable 4: Cable short check
enable2
Timer number select
Po TM Number
0~99: Timer Number set
Gun assignment select
Pp GunNumFix
ON: Fixed to GUN1 in odd-numbered series Fixed to GUN2 in
even-numbered series OFF: Can be set to any number.
Remote I/O select
Pq RemortI/O
ON :Enable(For DeviceNet) OFF :Disable
Current
detection
signal
output selection
Pr CurDetect
ON: Enable OFF: Disable
Step up Finish 2 series
output selection
Ps StepF2out
ON: Enable OFF: Disable
Step liner up
Pv Liner up
ON: Liner-up control OFF: Step-up control