Section 4: Chiller Installation
6
1. Install the wall hanger onto the wall according to the rough-in drawing.
See page 3.
The Wall hanger is shipped fastened to the back of the chiller unit.
2. Once the chiller unit is hung on the wall, Install a p-trap in the waste line and a shut off
valve in water supply line.
Refer to rough in drawing
for install locations and
dimensions
Install wall hanger bracket
with three chosen anchors
(not provided)
3. An in-
line strainer is furnished in “Water Supply” tube. Connect “Water Supply” tube to
shut-off valve. NOTE: This connection should not be a solder joint or flare connection to
allow access to the strainer for service. Using one of the 1-
3/4” diameter knockouts for a
waste line is not recommended because of a potential conflict with ADA toe space
clearance requirements. Check your local building code inspector for approval.
4. Rotate fan blade by hand to see that it is free of obstructions.
5. Leave the front panel off for the Bottle Filler installation.
P-Trap