QUASAR is a form of dispense point water treatment that utilizes UVC-LEDs to
inactivate pathogens.
Operation:
The QUASAR activation is automatic. The UVC-LED’s turn ON when water is
dispensed and OFF when the dispense stops.
During non-use periods the QUASAR automatically cycles ON for ten seconds every
ten minutes. This keeps the dispense point fresh and clean.
When the QUASAR is ON, the LED light near the top of the alcove will turn ON. The
LED will be BLUE when the QUASAR is working properly.
If QUASAR is not working properly, then the LED light will be RED. The light will
remain ON and the water dispense will be stopped until the problem is resolved.
IMPORTANT:
Never operate the QUASAR without water connected to the system.
Lack of water can cause the QUASAR to overheat.
7. QUASAR UVC
7. QUASAR UVC
7. QUASAR UVC
7. QUASAR UVC----LED OPERATION
LED OPERATION
LED OPERATION
LED OPERATION
DIAGRAM 8
12
Indicator Light
BLUE=operating normally
RED=QUASAR failure and
water will not dispense.