6. INSTALLATION:
6. INSTALLATION:
6. INSTALLATION:
6. INSTALLATION:
STEPS 10 through 17:
NOTE: This unit contains the QUASAR UVC LED.
Do not attempt to operate the
electronic bottle filler dispenser until the cooling tank is filled and the water filters
are flushed.
10.
Purging Air From Cooling Tank and Flushing Filters:
•
Remove top of unit by removing one screw on each side of the top.
•
Locate the ball valve as shown in Diagram 7
•
Place a container in the alcove
•
Open the ball valve and leave open until water comes out continuously without any
air. If filters are installed, continue to run water until the water runs clear. Then close
the Ball Valve.
11.
Check system for any leaks.
12.
Rotate the fan blade to see that it is free of obstructions.
13.
ENERGIZING UNIT: Check the available power supply against the water dispenser data
plate to ensure correct electrical service. This water dispenser is intended to be
connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL
requirements. Plug Power Supply Cord into outlet.
14.
Place bottle in alcove to purge additional air in Cooling Tank and water lines. The
Water Dispenser sensor will run for 20 seconds and shut-off. Do this 2 or 3 times until
a steady stream of water dispenses.
15.
SETTING UP PCB ELECTRONICS: Follow instructions in
Section 7
to change default
setting.
16.
Re-install Front Panel, and 2 screws.
17.
Set up is complete. Enjoy!
11
DIAGRAM 7
Ball Valve
TOP VIEW