B_1RREC / POU_1RREC Series
Installation & Service Instructions
030099-499 RevOrig
pg 8 of 22
© Copyright 2014 OASIS Europe
the ambient room temperature. The ambient water should be flushed after long periods of non
use.
Compressor
•
The compressor uses the hydrofluorocarbon refrigerant R134a which is a non-Ozone depleting
substance with a Global Warming Potential of 1,300. The compressor is controlled by an
electromechanical thermostat that controls the temperature of the water in the Reservoir.
•
The compressor is equipped with an automatic reset protector that disconnects the motor from
the line in case of an overload.
•
This unit is equipped with a sealed compressor that requires no additional lubrication.
Water Pipe and Fittings
•
The entire internal water circuit and all the components which come in contact with water are
made from food grade approved material
Mounting Feet
•
The unit is supplied with 4 mounting feet which can be used to level the cooler on uneven
surfaces.
Maintenance
•
Periodically remove dirt and lint from the condenser. Inspection should be done every three
months. If cleaning is required, disconnect the power supply cord, and then clean the condenser
with a small stiff non-wire brush. Following this procedure will ensure adequate air circulation
through the condenser for efficient and economical operation.
NOTE:
Under no circumstances should the cabinetry be cleaned using a water jet
•
WaterGuard helps prevent foreign matter from entering the cooling tank. Its parts should be
inspected, cleaned and replaced (if necessary) at regular intervals. Operation of the cooler
without WaterGuard components in place may allow airborne dust particles to enter the cooling
tank.
•
Cleaning of water contact components
o
The European Bottled Water Association recommends that water contact parts should be
cleaned and sanitised every 3 months. It is recommended that this process is carried out
by trained personnel
Water Valves:
•
Control of water dispensing is achieved by means of DC electrical solenoid valves. TWO or
FOUR valves are used depending on the model – one for cold water (24Vdc), one for hot water
or ambient water (24Vdc), TWO for carbonated water (24Vdc).
Panels:
•
All external molded panels are made from ABS plastic. The material used is UV resistant and
meets all CE and UL requirements for fire safety. All metal panels are made from galvanized
steel which is then painted. The galvanized coating provides increased resistance to rust and
corrosion.